Страница 2: ...Testing Baled Hay 5 Testing in the Windrow 7 Factors Affecting Your Reading 7 Range Of Moisture Content 7 Hay Temperature 8 Curing 8 Density 8 Use Of Preservatives 8 Sample Size 9 Testing for hops 10...

Страница 3: ...ing erases the readings Scale Button 3 Displays the meter scale hay or hops and acts as a toggle switch to change between two scales Also acts as an arrow button when pressed after the set point butto...

Страница 4: ...value To scroll forward to a higher value hold the set point button 4 while the current value is displayed and scroll to the set point value desired To scroll backward through the set point values pre...

Страница 5: ...tored in memory TAKING A READING TESTING BALED HAY Connect the probe to the external connector on the top of the meter Insert the probe into the bale Press the read button 1 The meter displays the MC...

Страница 6: ...ve This will make the moisture distribution in the sample more uniform Test B Attach the 831 short pin prod to the H 4 handle and connect the handle to the external connector on top of the meter Apply...

Страница 7: ...creases so does the conductivity Tests on hay at high moisture content over 25 are less accurate This is mostly due to the variability in moisture distribution The reduced level of accuracy in the hig...

Страница 8: ...ll ensure firmer and more uniform contact USE OF PRESERVATIVES Hay preservative or stabilizers may also have an effect on meter readings Normally a bale of hay treated with preservative will read high...

Страница 9: ...the moisture level in the hops that is in contact with the uninsulated tip of the prod Therefore it is very important to make a number of tests in all parts of a bale for proper testing Since moistur...