TABLE OF CONTENTS 

 

 
 

BD-10 Features  

 
4  

Before You Begin 

 
4  

Check Calibration 

 
4  

Taking a Reading 

 
4  

Using 6-40% Wood Scale 

 
4  

Paint Failure and Moisture 

 

EIFS (Exterior Insulation & Finish Systems) 

 
5  

Using 0-100 Reference Scale 

 

Testing Concrete Slabs for Flooring Applications  

 

Testing Brick or Concrete for Paint Application 

 
7  

Testing Plaster Walls, Sheetrock (Gypsum) 

 

Tracing Leaks  

 

Detecting Moisture in Insulation 

 

Care of Your Meter 

 

Service For Your Meter 

 
9  

Warranty 

 
10 

Wood conversion table 

 
 

Содержание BD-10

Страница 1: ...BD 10 BUILDING MATERIALS MOISTURE METER OPERATION MANUAL DELMHORST EUROPE TITANIUMLAAN 100 NL 5221 CK s HERTOGENBOSCH THE NETHERLANDS info delmhorst eu www MoistureMetersDelmhorst com 31 0 73 6395080...

Страница 2: ...5 EIFS Exterior Insulation Finish Systems 5 Using 0 100 Reference Scale 5 Testing Concrete Slabs for Flooring Applications 6 Testing Brick or Concrete for Paint Application 7 Testing Plaster Walls Sh...

Страница 3: ...staccurate method for measuring moisture 6 40 moisture range for wood 0 to 100 reference scale for non wood materials Analog readout Built in calibration check Temperature stable circuit Ergonomic cas...

Страница 4: ...ING A READING Remove the protective cover to expose the pins Check that the contact pins are firmly hand tightened USING 6 40 WOOD SCALE Align contact pins parallel to the grain pushing to their full...

Страница 5: ...mid section ofthe slab especiallyif the slab is on or below grade This will help determine ifthere is continuous moisture migration toward the surface If this condition exists the moisture movementma...

Страница 6: ...ccur These materials are frequentlyexposed to unusual moisture conditions thatallow them to absorb moisture through some exposed surface or some structural defect This is why it is importantto check t...

Страница 7: ...meter The following guidelines maybe used to interpretthe meter readings on plaster or sheetrock prior to painting or applying adhesives Green or dry 4 moisture Red or wet approximately5 Yellow Borde...

Страница 8: ...protective carrying case provided is an ideal storage place when the meter is not in use Change the 9 Volt battery as needed Continued use with a low battery may cause the meter to go out of calibrat...

Страница 9: ...instructions in the Care of Your Meter section Under no circumstances shall DELMHORSTbe liable for any incidental indirect special or consequential damages ofany type whatsoever including butnot limi...

Страница 10: ...10...