Power supplies
The S6010–ON supports two hot-swappable power supply units (PSUs) with integrated fans that provide cooling for the system.
The system supports AC or DC power supplies with two air-flow directions—from the I/O to the PSU side and from the PSU to the I/O
side. Two PSUs are required for full redundancy, but the system can operate with a single PSU.
The PSUs are field replaceable. When running with full redundancy—two power supplies installed and running, you can remove and replace
one PSU without disrupting traffic.
The S6010–ON does not support mixing PSU types. You cannot replace an AC PSU with a DC PSU and you cannot replace an AC-R PSU
with a DC-R PSU.
NOTE:
If you use a single PSU, install a blank plate in the other PSU slot. Dell recommends using power supply 1 (PSU1) as the
blank plate slot.
NOTE:
ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap when
handling the S6010–ON and its components.
CAUTION:
To prevent electrical shock, ensure that the S6010–ON is grounded properly. If you do not ground your equipment
correctly, excessive emissions may result. Use a qualified electrician to ensure that the power cables meet your local electrical
requirements.
Topics:
•
•
•
•
Components
The following power supply options are available for the S6010–ON:
•
AC power supply with integrated fan
•
AC power supply with integrated reverse flow fan
•
DC power supply with integrated fan
•
DC power supply with integrated reverse flow fan
Power supply unit 0, PSU 0, is on the left side of the chassis; power supply unit 1, PSU 1, is on the right side of the chassis.