6–Configuring RoCE
Configuring RoCE on the Adapter for Windows Server
52
BC0154503-00 B
2.
Select
Network Direct Mtu Size
from the Property menu. The network
direct MTU size must be less than the jumbo packet size. In this example,
select 1024. Click
OK
.
3.
Verify that RoCE is enabled on the adapter using Windows PowerShell
®
.
The
Get-NetAdapterRdma
command lists the adapters that support
RDMA—both ports are enabled.
PS C:\Users\Administrator>
Get-NetAdapterRdma
Name InterfaceDescription Enabled
----- -------------------- -------
SLOT 4 3 Port 1 QLogic FastLinQ QL45212... True
SLOT 4 3 Port 2 QLogic FastLinQ QL45212... True
4.
Verify that RoCE is enabled on the host operating system using PowerShell.
The
Get-NetOffloadGlobalSetting
command shows NetworkDirect is
enabled.
PS C:\Users\Administrators>
Get-NetOffloadGlobalSetting
ReceiveSideScaling : Enabled
ReceiveSegmentCoalescing : Enabled
Chimney : Disabled
TaskOffload : Enabled
NetworkDirect : Enabled
NetworkDirectAcrossIPSubnets : Blocked
PacketCoalescingFilter : Disabled
Содержание QLogic QL45212