Troubleshooting Your Enclosure
65
3
Re-install the
physical disk
in its original bay. See "Removing and Installing Physical Disks" on page 48.
If the problem persists, see "Getting Help" on page 69.
Problem
•
Physical disk
status LED is flashing amber.
Action
1
Review MD Storage Manager for possible recovery actions.
NOTE:
If a physical disk rebuild is under way, allow the rebuild to complete.
2
Remove the
physical disk
from the enclosure. See "Removing and Installing Physical Disks" on
page 48.
3
Inspect the disk and midplane connectors for obvious damage.
4
Re-install the disk in its original bay. See "Removing and Installing Physical Disks" on page 48.
If the problem persists, see "Getting Help" on page 69.
Problem
•
Multiple
physical disk
s are not seen in MD Storage Manager.
Action
1
Make sure that all cables are attached correctly according to the enclosure mode you selected. For more
information on enclosure modes, see "Cabling Your RAID Enclosure" on page 19.
2
Verify that the SAS port link status LED is solid green for each port that is connected to a cable. If it is
not, see "Back-Panel Indicators and Features" on page 13.
3
If you reseated cables, reboot the host server.
If the problem persists, see "Getting Help" on page 69.
Troubleshooting Enclosure Connections
Problem
•
Enclosure is not seen by attached host controller.
Action
•
Inspect RAID controller module cables for connectivity problems, such as damaged or disconnected
cables and poor connections. For detailed cabling instructions, see "Cabling Your RAID Enclosure" on
page 19.