8
About Your System
Indicators on the Enclosure Bezel
An optional locking bezel can be installed on the front of the enclosure to limit access.
Figure 1-1
illustrates the indicators and components on the bezel. Table 1-1 lists conditions indicated by the lights on
the bezel.
For information on installing and removing the bezel, see "Removing and Replacing the Front
Bezel."
Figure 1-1.
LEDs on the Front Bezel
Table 1-1.
Front Bezel Indicators
Item LED Indicator
LED Icon
Condition
1
Split mode (green)
When lit, indicates the enclosure is in split mode;
otherwise, the enclosure is in unified mode. For more
information on both modes, see “Unified Mode and Split
Mode.”
2
Power (green)
When lit, at least one power supply is supplying power to
the enclosure.
3
Enclosure status
(blue/amber)
Steady amber:
Power is on and enclosure is in reset state
Steady blue:
Power is on and enclosure status is OK.
Flashing blue:
Host server is identifying the enclosure.
Flashing amber:
Enclosure is in fault state.
1
2
3