Dell PowerEdge R640XL Скачать руководство пользователя страница 19

Gen14 Dell Hardware

19

Security Analytics

Configuration Guide

NOTE: 

If you choose to enable DHCP, it is recommended that you use the DHCP reservation feature of your DHCP server 

to statically map the MAC address of the iDRAC interface to an IP address.
5. In the lower right, click 

Finish

 and follow the on-screen prompts to save and exit the System Setup page.

Initialize and License the Server

The server appliance (SA

-

SRVG8-20 or SA

-

SRVG8-40), as Central Manager (CM) or Sensor, must be initialized and licensed 

before it can be used in a Security Analytics system. If this has already been done per the instructions on the 

Security 

Analytics Gen14 Dell Server Quick Start Guide

, it need not be done again.

Initialize the Server 

If the server appliance (SA

-

SRVG8-20 or SA

-

SRVG8-40) has not yet been initialized, perform the following steps:

1. Power on the server (if it is not already powered on). After several minutes, you are prompted to log in to the command-

line interface (CLI).

2. Using the connected USB keyboard, enter default credentials: 

admin | Solera

NOTE: 

You can also log in by connecting to the appliance’s 

MGMT 0:0

 port with a laptop running SSH (via IP address 

192.168.20.20

).

3. Configure the management IP address, netmask, and gateway with the following CLI command, specifying the netmask 

in dotted-decimal format (255.255.255.0): 

sudo cfg_bond_interface.py -i eth0 -n <IP>/<netmask> -g <gateway>

4. When prompted, enter the sudo password: 

Solera

5. Open a browser, navigate to the address just specified, and log in with default credentials: 

admin | Solera

6. When prompted, accept the 

EULA

.

7. Configure the 

Initial Settings

 page. For installation instructions, select 

Settings > Help

.

8. Click 

Save

. You are prompted to license the server.

License the Server

If the server (SA

-

SRVG8-20 or SA

-

SRVG8-40) has not yet been licensed, perform the following steps:

1. After completing the initial configuration, you are prompted with the 

License Details

 dialog.

NOTE: 

You can also update or change an existing license. To do so, select 

Menu > Settings > About

 and then click 

License Details

.

2. Retrieve your license key from the Broadcom Support Portal (

support.broadcom.com/security

), as instructed in the 

eFulfillment message from Broadcom.

3. If your server has Internet access, do the following:

User Configuration

User Name

(as desired)

Change Password

(as desired)

Lifecycle Controller

Collect System Inventory on Restart

Disabled

Page

Attribute

Value

Содержание PowerEdge R640XL

Страница 1: ...Security Analytics Gen14 Dell Hardware Configuration Guide 18 Dec 2020 ...

Страница 2: ...without further notice to any products or data herein to improve reliability function or design Information furnished by Broadcom is believed to be accurate and reliable However Broadcom does not assume any liability arising out of the application or use of this information nor the application or use of any product or circuit described herein neither does it convey any license under its patent rig...

Страница 3: ... 6 Security Analytics Systems 8 Chapter 2 Connect the Storage Arrays 9 Cabling for Small Sensor Systems 9 Cabling for Large Sensor Systems 12 Chapter 3 First time Power On and Initialization 18 Powering On Sensor Systems 18 Configure the Server s iDRAC Port 18 Initialize and License the Server 19 Configure Network Settings for the Storage Array 20 Chapter 4 Disk Array Configuration 21 Clear Disk A...

Страница 4: ...figuration Guide for Gen12 Dell Hardware WARNING You cannot combine Gen14 Dell hardware with Gen12 or Gen13 Dell hardware or with SA S500 Series servers The Gen14 Dell hardware documented in this guide should only be used as indicated with the specified Symantec models Requirements The Security Analytics systems documented in this guide require the following Server Symantec SA SRVG8 20 Dell PowerE...

Страница 5: ... array modu Rackmount the storage array Install drives in the SA STAG8 5U840storage array Connect cables Power on the system Configure network settings for the storage array Where to Go for Help Symantec Technical Support For Symantec Technical Support case management licenses and product downloads go to support broadcom com security Security Analytics Help and Documentation For Security Analytics...

Страница 6: ... as a Sensor connected to storage arrays They include the following iDRAC MGMT Ethernet LAN and RAID controller SAS ports Storage Array I O Configuration The following storage arrays can be used in Sensor Systems They include the following MGMT and SAS ports SA SRVG8 20 Server Rear Panel SA SRVG8 40 Server Rear Panel SA STAG8 2U144 Storage Array Rear Panel ...

Страница 7: ...Gen14 Dell Hardware 7 Security Analytics Configuration Guide SA STAG8 5U840 Storage Array Rear Panel SA STXG8 2X144 Expansion Enclosure Rear Panel ...

Страница 8: ...G8 2U144 144TB 10 1GbE 2 1 SA SRVG8 20 12TB 1 SA STAG8 2U144 144TB 1 3 SA STXG8 2X144 144TB 432TB 10 1GbE 3 1 SA SRVG8 20 12TB 1 SA STAG8 5U840 840TB 10 1GbE Large Sensor 1 1 SA SRVG8 40 12TB 1 SA STAG8 2U144 144TB 10 1GbE 25 10 1GbE 2 1 SA SRVG8 40 12TB 1 SA STAG8 2U144 144TB 1 3 SA STXG8 2X144 144TB 432TB 10 1GbE 25 10 1GbE 3 1 SA SRVG8 40 12TB 1 SA STAG8 5U840 840TB 10 1GbE 25 10 1GbE 4 1 SA SR...

Страница 9: ...o HD Mini SAS cables included with the storage array or equivalent Cabling for Small Sensor Systems Security Analytics Small Sensor Systems include the following Small Sensor System 1 1 SA SRVG8 20 1 SA STAG8 2U144 Small Sensor System 2 1 SA SRVG8 20 1 SA STAG8 2U144 1 3 SA STXG8 2X144 Small Sensor System 3 1 SA SRVG8 20 1 SA STAG8 5U840 Small Sensor System 1 SAS cabling for the Small Sensor Syste...

Страница 10: ...RVG8 20 Sensor SA STAG8 2U144 Storage Array SA STXG8 2X144 Expansion Enclosure Up to 3 RAID Cont Port Cont Mod Port Cont Mod Port Cont Mod Port Cont Mod Port Slot 1 SAS 0 A Top SAS 0 Slot 1 SAS 1 B Btm SAS 0 A Top SAS Exp A Top SAS A B Btm SAS Exp B Btm SAS C A Top SAS C A Top SAS A B Btm SAS C B Btm SAS A A Top SAS C A Top SAS A B Btm SAS C B Btm SAS A Cabling Guide for Small Sensor System 2 ...

Страница 11: ...m 3 SAS cabling for the Small Sensor System 3 is as follows 1 SA SRVG8 20 1 SA STAG8 5U840 Server SA SRVG8 20 Sensor SA STAG8 5U840 Storage Array RAID Controller Port Controller Module Port Slot 1 SAS 0 A Left SAS 0 Slot 1 SAS 1 B Right SAS 0 Cabling Guide for Small Sensor System 3 ...

Страница 12: ...8 5U840 Large Sensor System 4 1 SA SRVG8 40 2 SA STAG8 2U144 Large Sensor System 5 1 SA SRVG8 40 2 SA STAG8 2U144 1 3 SA STXG8 2X144 Large Sensor System 6 1 SA SRVG8 40 2 SA STAG8 5U840 Large Sensor System 1 SAS cabling for the Large Sensor System 1 is as follows 1 SA SRVG8 40 1 SA STAG8 2U144 SA SRVG8 40 Sensor SA STAG8 2U144 Storage Array RAID Controller Port Controller Module Port Slot 1 SAS 0 ...

Страница 13: ...U144 Storage Array SA STXG8 2X144 Expansion Enclosures Up to 3 RAID Cont Port Cont Mod Port Cont Mod Port Cont Mod Port Cont Mod Port Slot 1 SAS 0 A Top SAS 0 Slot 1 SAS 1 B Btm SAS 0 Slot 3 SAS 0 A Top SAS 1 Slot 3 SAS 1 B Btm SAS 1 A Top SAS EXP A Top SAS A B Btm SAS EXP B Btm SAS C A Top SAS C A Top SAS A B Btm SAS C B Btm SAS A A Top SAS C A Top SAS A B Btm SAS C B Btm SAS A Cabling Guide for ...

Страница 14: ...ge Sensor System 3 is as follows 1 SA SRVG8 40 1 SA STAG8 5U840 Server SA SRVG8 40 Sensor SA STAG8 5U840 Storage Array RAID Controller Port Controller Module Port Slot 1 SAS 0 A Left SAS 0 Slot 1 SAS 1 B Right SAS 0 Slot 3 SAS 0 A Left SAS 1 Slot 3 SAS 1 B Right SAS 1 Cabling Guide for Large Sensor System 3 ...

Страница 15: ...System 4 is as follows 1 SA SRVG8 40 2 SA STAG8 2U144 SA SRVG8 40 Sensor SA STAG8 2U144 Storage Array SA STAG8 2U144 Expansion Enclosure RAID Cont Port Cont Mod Port Cont Mod Port Slot 1 SAS 0 A Top SAS 0 Slot 1 SAS 1 B Btm SAS 0 Slot 3 SAS 0 A Top SAS 0 Slot 3 SAS 1 B Btm SAS 0 Cabling Guide for Large Sensor System 4 ...

Страница 16: ...TAG8 2U144 Storage Array SA STXG8 2X144 Expansion Enclosure Up to 3 RAID Cont Port Cont Mod Port Cont Mod Port Cont Mod Port Cont Mod Port Cont Mod Port Slot 1 SAS 0 A Top SAS 0 Slot 1 SAS 1 B Btm SAS 0 A Top SAS EXP A Top SAS A B Btm SAS EXP B Btm SAS C A Top SAS C A Top SAS A B Btm SAS C B Btm SAS A Slot 3 SAS 0 A Top SAS 0 Slot 3 SAS 1 B Btm SAS 0 A Top SAS EXP A Top SAS A B Btm SAS EXP B Btm S...

Страница 17: ...tem 6 is as follows 1 SA SRVG8 40 2 SA STAG8 5U840 SA SRVG8 40 Sensor SA STAG8 5U840 Storage Array SA STAG8 5U840 Storage Array RAID Cont Port Cont Module Port Cont Module Port Slot 1 SAS 0 A Left SAS 0 Slot 1 SAS 1 B Right SAS 0 Slot 3 SAS 0 A Left SAS 0 Slot 3 SAS 1 B Right SAS 0 Cabling Guide for Large Sensor System 6 ...

Страница 18: ...U144 and SA STXG8 2X144 the System Power LED turns green For the SA STAG8 5U840 the Power On Standby LED turns green Configure the Server s iDRAC Port The iDRAC port alerts administrators about issues with the server appliance SA SRVG8 20 and SA SRVG8 40 and provides remote management thereby reducing the need for physical access to the server The iDRAC port should be configured when first booting...

Страница 19: ...ce s MGMT 0 0 port with a laptop running SSH via IP address 192 168 20 20 3 Configure the management IP address netmask and gateway with the following CLI command specifying the netmask in dotted decimal format 255 255 255 0 sudo cfg_bond_interface py i eth0 n IP netmask g gateway 4 When prompted enter the sudo password Solera 5 Open a browser navigate to the address just specified and log in with...

Страница 20: ...ile license tgz Store this file in a secure location that is not on the server Configure Network Settings for the Storage Array Network settings for storage arrays must be configured before they can communicate with Sensors If this has already been done per the instructions on the Security Analytics Gen14 Dell Storage Quick Start Guide it need not be done again Network settings for expansion enclo...

Страница 21: ...G If you are re configuring an existing Sensory system run the scotus stop command to cease all processes in Security Analytics before re configuring the disk arrays To clear disk arrays on a storage array 1 Verify the following requirements have been met as instructed in the Security Analytics Server Quick Start Guide and Security Analytics Storage Quick Start Guide The Sensor s eth0 bond0 port i...

Страница 22: ...son Run the following command to configure the disk array powervault_config py etc solera powervault config powervault 10 10 10 10 json Session Established Command completed successfully The host s were modified 2020 08 04 18 59 53 Command completed successfully The host s were modified 2020 08 04 18 59 58 Command completed successfully The host s were created 2020 08 04 19 00 03 Command completed...

Страница 23: ...d successfully capture1 Mapping succeeded Initiator 52cea7f043a16a01 was mapped for volume capture1 with LUN 2 2020 08 04 17 45 50 Command completed successfully 2020 08 04 17 45 55 Command completed successfully capture2 The volume was created 2020 08 04 17 45 58 Mapping succeeded Initiator 52cea7f043a16a00 was mapped for volume capture2 with LUN 3 capture2 2020 08 04 17 46 00 Command completed s...

Страница 24: ...ilable storage space for each Restarting multipathd Stopping multipathd Rescanning the Host Bus Adapters Rescanning HBA sys class sas_host host1 device scsi_host host1 scan Starting multipathd The following dm devices are now detected by the host 21T 3600c0ff00051d227691f295f01000000 dm 1 DellEMC ME4 85T 3600c0ff00051d1a8701f295f01000000 dm 0 DellEMC ME4 WARNING fdisk GPT support is currently new ...

Страница 25: ...d ds index M dm 4 Restarting multipathd Stopping multipathd Rescanning the Host Bus Adapters Rescanning HBA sys class sas_host host1 device scsi_host host1 scan Rescanning HBA sys class sas_host host16 device scsi_host host16 scan Starting multipathd The following dm devices are now detected by the host 96T 3600c0ff00051c606c39e295f01000000 dm 4 DellEMC ME4 150T 3600c0ff00051c606ed9e295f01000000 d...

Страница 26: ... Hardware 26 Security Analytics Configuration Guide 5 Enter the following command to reboot the storage array sudo reboot 6 After rebooting enter the following command for a report of the array configuration df h ...

Страница 27: ...2020 12 18 11 28 23 ...