Configuration Guide
Chapter 3: First-time Power On and Initialization
NOTE:
Security Analytics 8.1.3 or later is required when using Gen14 Dell servers and storage arrays.
Powering On Sensor Systems
When powering on Sensor Systems, make sure that components are powered on in the following order:
3. Power on any expansion enclosures (SA
-
STXG8-2X144). Wait until the expansion enclosures’ drive lights are lit (solid)
before proceeding.
4. Power on the storage arrays (SA
-
STAG8-2U144 or SA
-
STAG8-5U840). Wait until storage arrays’ drive lights the are lit (solid)
before proceeding.
5. Power on the Sensor (SA
-
SRVG8-20 or SA
-
SRVG8-40).
6. Once all components are powered on, verify the following:
For the SA
-
STAG8-2U144 and SA
-
STXG8-2X144, the
System Power LED
turns green.
For the SA
-
STAG8-5U840, the
Power On/Standby LED
turns green.
Configure the Server’s iDRAC Port
The iDRAC port alerts administrators about issues with the server appliance (SA
-
SRVG8-20 and SA
-
SRVG8-40) and
provides remote management, thereby reducing the need for physical access to the server. The iDRAC port should be
configured when first booting the server.
To configure the server’s iDRAC port:
1. When the server boots, look for following menu screen:
F2 = System Setup
F10 = Lifecycle Controller
F11 = BIOS Boot Manager
F12 = PXE Boot
2. Press
F2
to enter the system setup.
3. On the System Setup Main Menu, select
iDRAC Settings
.On the System Setup Main Menu, select
iDRAC Settings
.
4. Configure the following iDRAC settings:
Page
Attribute
Value
Network Settings
Enable NIC
Enabled
NIC Selection
Dedicated
Failover Network
None
Enable DHCP
(as desired)
IP Address
(as desired)
Gateway
(as desired)
Содержание PowerEdge R640XL