34
About Your System
E1920 iDRAC6 Upgrade
Failed
The iDRAC6 Express
Card is not installed
properly or the card is bad.
Reseat the iDRAC6
Express Card. If the
problem persists, see
"Getting Help" on
page 187.
E1A14 SAS cable A
failure.
Check
connection.
SAS cable A is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 187.
E1A15 SAS cable B
failure.
Check
connection.
SAS cable B is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 187.
E1A1D Control panel
USB cable not
detected.
Check cable.
USB cable to the control
panel is missing or bad.
Reseat the cable.
If the problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 187.
E2010 Memory not
detected.
Inspect DIMMs.
No memory was detected
in the system.
Install memory or reseat
memory modules.
See "Installing Memory
Modules" on page 108 or
"Troubleshooting System
Memory" on page 165.
E2011 Memory
configuration
failure.
Check DIMMs.
Memory detected,
but is not configurable.
Error detected during
memory configuration.
See "Troubleshooting
System Memory" on
page 165.
Code
Text
Causes
Corrective Actions
book.book Page 34 Tuesday, August 24, 2010 1:47 PM
Содержание POWEREDGE R515
Страница 156: ...156 Installing System Components ...
Страница 176: ...176 Troubleshooting Your System ...
Страница 186: ...186 Jumpers and Connectors ...
Страница 188: ...188 Getting Help ...
Страница 194: ...194 Index W warning messages 55 warranty 56 wet system troubleshooting 158 ...