NOTE:
It is recommended that you always use an antistatic mat and antistatic strap while working on components inside
the system.
CAUTION:
To ensure proper operation and cooling, all system bays and fans must always be populated with a
component or a blank.
NOTE:
While replacing the hot swappable PSU, after next server boot; the new PSU automatically updates to the same
firmware and configuration of the replaced one. For more information about the Part replacement configuration, see the
Lifecycle Controller User's Guide
at
https://www.dell.com/idracmanuals
NOTE:
While replacing faulty storage controller, FC, or NIC card with the same type of card, after you power on the
system; the new card automatically updates to the same firmware and configuration of the faulty one. For more information
about the Part replacement configuration, see the
Lifecycle Controller User's Guide
at
https://www.dell.com/idracmanuals
.
Before working inside your system
Prerequisites
Follow the safety guidelines listed in the
.
Steps
1. Power off the system and all attached peripherals.
2. Disconnect the system from the electrical outlet, and disconnect the peripherals.
3. If applicable, remove the system from the rack.
For more information, see the
Rail Installation Guide
relevant to your rail solutions at
4. Remove the system cover.
After working inside your system
Prerequisites
Follow the safety guidelines listed in
.
Steps
Reconnect the peripherals and connect the system to the electrical outlet, and then power on the system.
Recommended tools
You need the following tools to perform the removal and installation procedures:
●
Key to the bezel lock. The key is required only if your system includes a bezel.
●
Phillips #1 screwdriver
●
Phillips #2 screwdriver
●
Torx #T20 screwdriver
●
Torx #T30 screwdriver
●
5 mm hex nut screwdriver
●
Plastic scribe
●
1/4-inch flat blade screwdriver
●
Wrist grounding strap connected to the ground
●
ESD mat
You need the following tools to assemble the cables for a DC power supply unit:
●
AMP 90871-1 hand-crimping tool or equivalent
●
Tyco Electronics 58433-3 or equivalent
●
Wire-stripper pliers to remove insulation from size 10 AWG solid or stranded, insulated copper wire
26
Installing and removing system components
Содержание PowerEdge R450
Страница 15: ...Figure 11 Memory information Dell EMC PowerEdge R450 system overview 15 ...
Страница 16: ...Figure 12 Service information electrical overview 16 Dell EMC PowerEdge R450 system overview ...
Страница 17: ...Figure 13 Service information mechanical overview Dell EMC PowerEdge R450 system overview 17 ...