Jumpers and Connectors
Disabling a Forgotten Password
The system's software security features include a system password and a setup
password, which are discussed in detail in "Using the System Setup Program
and Boot Manager" on page 23. The password jumper enables these password
features or disables them and clears any password(s) currently in use.
CAUTION:
See "Protecting Against Electrostatic Discharge" in the safety
instructions that came with the system.
1
Turn off the system, including any attached peripherals, and disconnect
the system from the electrical outlet.
2
Open the system. See "Opening and Closing the System" on page 45.
3
Remove the jumper plug from the password jumper.
See Figure 6-1 to locate the password jumper (labeled "PWRD_EN") on
the system board.
4
Close the system. See "Closing the System" on page 46.
The existing passwords are not disabled (erased) until the system boots
with the password jumper plug removed. However, before you assign a new
system and/or setup password, you must install the jumper plug.
NOTE:
If you assign a new system and/or setup password with the jumper
plug still removed, the system disables the new password(s) the next time it
boots.
5
Turn off the system, including any attached peripherals, and disconnect
the system from the electrical outlet.
6
Open the system. See "Opening and Closing the System" on page 45.
7
Install the jumper plug on the password jumper.
8
Close the system. See "Closing the System" on page 46.
9
Assign a new system and/or setup password.
To assign a new password using the System Setup program, see "Assigning
a System Password" on page 38.
Содержание POWEREDGE E11S
Страница 1: ...Dell PowerEdge T110 II Systems Owner s Manual Regulatory Model E11S Series Regulatory Type E11S002 ...
Страница 22: ...22 About Your System ...
Страница 98: ...98 Installing System Components ...
Страница 114: ...114 Troubleshooting Your System ...
Страница 124: ...124 Getting Help ...
Страница 130: ...130 Index ...