Rack Installation Guide
15
Installing the System in the Rack
CAUTION:
If you are installing more than one system, install the first system in the lowest available position
in the rack.
CAUTION:
Because of the size and weight of the system, never attempt to install the system in the mounting rails
by yourself.
CAUTION:
Never pull more than one system out of the rack at a time.
1
Pull the two inner slide assemblies out of the rack until they lock in the fully extended position.
2
Lift the system into position above the extended slides.
Using a minimum of two persons, each person should place one hand on the front-bottom of the
system and the other hand on the back-bottom of the system.
The three shoulder screws on each side of the system fit into the corresponding J-slots on the inner
slide assemblies (see Figure 1-7).
3
Lower the back of the system while aligning the back shoulder screws on the sides of the system
with the back J-slots on the slide assemblies.
Figure 1-7.
Installing the System in the Rack
1
system locking mechanism
2
shoulder screws
3
J-slots
1
2
3
Содержание PowerEdge 2900
Страница 2: ......
Страница 3: ...Rack Installation Guide ...
Страница 6: ...4 Contents ...
Страница 23: ...Guide d installation du rack ...
Страница 26: ...24 Sommaire ...
Страница 44: ...42 Guide d installation du rack ...
Страница 45: ...Rack Installationsanleitung ...
Страница 48: ...46 Inhalt ...
Страница 67: ...ラック取り付けガイド ...
Страница 70: ...68 目次 ...
Страница 88: ...86 ラック取り付けガイド ...
Страница 89: ...Guía de instalación del rack ...
Страница 92: ...90 Contenido ...
Страница 110: ...108 Guía de instalación del rack ...