Information Update
19
E171F
PCIE Fatal Err
B## D## F##
The system BIOS
has reported a PCIe
fatal error on a
component that
resides in PCIe
configuration space
at bus ##, device
##, function ##.
Remove and reseat
the PCIe expansion
cards. If the
problem persists,
see
"Troubleshooting
Expansion Cards"
in the
Hardware
Owner’s Manual.
PCIE Fatal Err
Slot #
The system BIOS
has reported a PCIe
fatal error on a
component that
resides in the
specified slot.
Reinstall the
expansion-card riser.
See "Expansion
Card Risers" in the
Hardware Owner’s
Manual.
If the problem
persists, the riser
card or system board
is faulty. See
"Getting Help"
in the
Hardware
Owner’s Manual.
E1914
DRAC5 Conn2
Cbl
DRAC 5 cable is
missing or
disconnected.
Reconnect the
cable. See
"Installing a RAC
Card" in the
Hardware Owner’s
Manual.
E1B01
USB#
Overcurrent
Device plugged in
the specified USB
port caused an
overcurrent
condition.
Reseat the device
cable. If the
problem persists,
replace or remove
the device.
Table 1-2.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions
Содержание PowerEdge 1950
Страница 1: ...Dell PowerEdge 1950 Systems Information Update ...
Страница 27: ...Dell PowerEdge 1950 系统 信息更新 ...
Страница 51: ...Systèmes Dell PowerEdge 1950 Mise à jour des informations ...
Страница 81: ...Dell PowerEdge 1950 Systeme Informationsaktualisierung ...
Страница 111: ...Dell PowerEdge 1950 システム アップデート情報 ...
Страница 139: ...Dell PowerEdge 1950 시스템 설명서 갱신본 ...
Страница 164: ...164 정보 갱신본 ...
Страница 165: ...Sistemas Dell PowerEdge 1950 Actualización de información ...