Information Update
17
E1625
PS AC Current
Power source is out
of acceptable range.
Check the AC
power source.
E1711
PCI PERR B##
D## F##
The system BIOS
has reported a PCI
parity error on a
component that
resides in PCI
configuration space
at bus ##, device
##, function ##.
Remove and reseat
the PCIe expansion
cards. If the
problem persists,
see
"Troubleshooting
an Expansion Card"
in the
Hardware
Owner’s Manual.
PCI PERR Slot
#
The system BIOS
has reported a PCI
parity error on a
component that
resides in the
specified PCIe slot.
Reinstall the
expansion-card riser.
See "Expansion
Card Risers" in the
Hardware Owner’s
Manual.
If the problem
persists, the riser
card or system board
is faulty. See
"Getting Help"
in the
Hardware
Owner’s Manual.
Table 1-2.
LCD Status Messages
(continued)
Code
Text
Causes
Corrective Actions