122
Configuring System Information
Figure 6-36. Integrated Cable Test for Copper Cables
•
Port
— The port to which the cable is connected.
•
Test Result
— The cable test results. Possible values are:
–
No Cable
— There is no cable connected to the port.
–
Open Cable
— The cable is connected on only one side.
–
Short Cable
— A short has occurred in the cable.
–
OK
— The cable passed the test.
–
Fiber Cable
— A fiber cable is connected to the port.
•
Cable Fault Distance
— The distance from the port where the cable error occurred.
•
Last Update
— The last time the port was tested.
•
Approximate Cable Length
— The approximate cable length. This test can only be performed when the
port is up and operating at 1 Gbps.
Performing a Cable Test
1
Ensure that both ends of the copper cable are connected to a device.
2
Open the
Integrated Cable Test for Copper Cables
page.
3
Click
Test Now
.
The copper cable test is performed, and the results are displayed on the
page.