Using the CLI
41
2
Connect the DB9 null-modem or cross over cable to the RS-232 serial port of the Dell
Remote Access Controller / Modular Chassis (DRAC/MC) in the Dell Modular Server
Chassis to the RS-232 serial port of the terminal or computer running the terminal emulation
application.
NOTE:
The default data rate of the DRAC/MC is 115200.
a
Set the data format to 8 data bits, 1 stop bit, and no parity.
b
Set Flow Control to
none
.
c
Under
Properties
, select
VT100 for Emulation
mode.
d
Select
Terminal keys
for
Function, Arrow, and Ctrl keys
. Ensure that the setting is for
Terminal keys
(not
Windows keys
).
NOTICE:
When using HyperTerminal with Microsoft® Windows 2000, ensure that Windows® 2000
Service Pack 2 or later is installed. With Windows 2000 Service Pack 2, the arrow keys function properly
in HyperTerminal’s VT100 emulation. Go to www.microsoft.com for information on Windows 2000 service
packs.
On the console monitor, the DRAC/MC application displays a login screen.
3
Log in onto the DRAC/MC using the default username "root" and password "calvin".
The DRAC/MC CLI command prompt "DRAC/MC:" is displayed.
For more information, see
Dell Modular Server System User's Guide
.
4
If Dell Modular Server Chassis is off then power it on using the following DRAC/MC CLI
command:
racadm chassisaction -m chassis powerup
NOTE:
The Ethernet Switch Module inserted into the Chassis I/O bay is powered on automatically when
the Dell Modular Server Chassis is powered on. For further details on configuring the Dell Modular
Server Chassis via the DRAC/MC CLI interface, please see the
Dell Remote Access Controller / Modular
Chassis User's Guide
.
5
Power cycle the Ethernet Switch Module using the following DRAC/MC CLI command:
racadm chassisaction -m switch-N powercycle
where N is the Chassis I/O Module bay number in which the Ethernet Switch Module is
inserted.
6
Redirect the DRAC/MC serial console to the Ethernet Switch Module internal serial console
interface. This action is performed by entering the CLI command at the command prompt of
the DRAC/MC CLI.
connect switch-N
where N is the Chassis I/O Module bay number in which the Ethernet Switch Module is
inserted.
Содержание PowerConnect 5316M
Страница 1: ...w w w d e l l c o m s u p p o r t d e l l c o m Dell PowerConnect 5316M CLI Reference Guide ...
Страница 19: ...Contents 19 show dot1x advanced 356 ...
Страница 20: ...20 Contents ...
Страница 44: ...24 Command Groups ...
Страница 56: ...36 Command Modes ...
Страница 66: ...46 Using the CLI ...
Страница 92: ...72 Address Table Commands ...
Страница 108: ...88 Clock ...
Страница 140: ...120 Ethernet Configuration Commands ...
Страница 156: ...136 IGMP Snooping Commands ...
Страница 178: ...158 Line Commands ...
Страница 188: ...168 LLDP Commands ...
Страница 198: ...178 PHY Diagnostics Commands ...
Страница 206: ...186 Port Monitor Commands ...
Страница 216: ...196 QoS Commands ...
Страница 238: ...218 RMON Commands ...
Страница 258: ...238 SNMP Commands ...
Страница 284: ...264 Spanning Tree Commands ...
Страница 294: ...274 SSH Commands ...
Страница 304: ...284 Syslog Commands ...
Страница 332: ...312 User Interface ...
Страница 348: ...328 VLAN Commands ...
Страница 360: ...340 Web Server ...