2. Release latch
3.
Strip the insulation from the ends of the DC power wires, exposing approximately 13
mm (0.5 inch) of copper wire.
WARNING: Reversing polarity when connecting DC power wires can
permanently damage the power supply or the system.
4.
Insert the copper ends into the mating connectors and tighten the captive screws at
the top of the mating connector using a #2 Phillips screwdriver.
WARNING: To protect the power supply from electrostatic discharge, you
must cover the captive screws with the rubber cap before inserting the mating
connector into the power supply.
5.
Rotate the rubber cap clockwise to fix it over the captive screws.
6.
Insert the mating connector into the power supply.
Figure 19. Assembling the DC Input Power Wires
1. DC power socket
2. Rubber cap
3. Captive screws (2)
4. DC power connector
5. Wire (-48V)
6. Wire RTN
7. Grounding Wire
29
Содержание Networking S5000
Страница 2: ......
Страница 3: ...Dell Networking S5000 Getting Started Guide ...
Страница 49: ...Dell Networking S5000 Handbuch zum Einstieg ...
Страница 100: ...52 ...
Страница 101: ...Dell Networking S5000 Guía de introducción ...
Страница 151: ...Dell Networking S5000 Guide de mise en route ...
Страница 201: ...Dell Networking S5000 מדריך תחילת עבודה ...
Страница 244: ...44 ...
Страница 245: ...Dell Networking S5000 Руководство по началу работы ...
Страница 298: ...54 ...
Страница 299: ...Dell Networking S5000 Başlangıç Kılavuzu ...
Страница 346: ......