background image

Dell Networking S4048–Open Networking (ON) 
Installation Guide

January 2017

Содержание Networking S4048

Страница 1: ...Dell Networking S4048 Open Networking ON Installation Guide January 2017 ...

Страница 2: ...e to hardware or loss of data and tells you how to avoid the problem WARNING A WARNING indicates a potential for property damage personal injury or death Copyright 2017 Dell Inc or its subsidiaries All rights reserved Dell EMC and other trademarks are trademarks of Dell Inc or its subsidiaries Other trademarks may be trademarks of their respective owners 2017 01 Rev A02 ...

Страница 3: ...3 Storing components 13 4 NEBS compliance 15 Important information 15 5 S4048 ON installation 16 Unpack the S4048 ON system 16 Unpack 16 Rack or cabinet hardware installation 17 Rack mount safety considerations 17 ReadyRails system installation 17 Two post flush mount configuration 18 Two post center mount configuration 19 Four post threaded configuration 20 S4048 ON installation 21 1U front rack ...

Страница 4: ... ONIE Service Discovery on the S4048 ON System 36 9 Specifications 37 Chassis physical design 37 IEEE standards 38 Agency compliance 38 Network Equipment Building Systems NEBS Compliance 38 USA Federal Communications Commission FCC Statement 38 European Union EMC Directive Conformance Statement 39 Japan VCCI Compliance for Class A Equipment 40 Korean Certification of Compliance 40 Safety Standards...

Страница 5: ...servicing WARNING This equipment contains optical transceivers which comply with the limits of Class 1 laser radiation Figure 1 Class 1 laser product NOTE When no cable is connected visible and invisible laser radiation may be emitted from the aperture of the optical transceiver ports Avoid exposure to laser radiation and do not stare into open apertures Related documents For more information abou...

Страница 6: ...tical uplinks to the 40 Gbps switching fabric in the core The S4048 ON has Forty eight ports of 10G SFP ports for a 1 10 Gbps transceiver Six 40 Gbps fixed QSFP optical ports for a 40 Gbps transceiver Serial RS 232 port RJ 45 and MicroUSB RJ 45 management port The S4048 ON I O side includes Forty eight fixed SFP and six fixed QSFP ports Management port USB 2 0 port Serial RS 232 port RJ 45 and Mic...

Страница 7: ...for 40 Gbps transceivers One Micro USB serial console port One universal serial bus USB Type A port for more file storage Rangeley Central processing unit CPU system with large memory with 2 GB DDR III RAM Temperature monitoring Software readable thermal monitor Real time clock RTC support Hot plug redundant power supply Power management monitoring Removable fans Standard 1U chassis Physical dimen...

Страница 8: ...48 ON includes LED displays on both the I O Port and PSU side of the chassis as shown For LED information see your third party operating software documentation Figure 4 S4048 ON LEDs 1 SFP port Link and activity LEDs 2 System LEDs 3 QSFP port LEDs 4 FAN LED 5 Management port LEDs 6 PSU LED 8 The S4048 ON system ...

Страница 9: ...ivity LEDs Table 1 S4048 ON LED behavior LED Description System Status Health LED Solid green Normal operation Blinking green Booting Solid amber Critical system error Blinking amber Non critical system error fan failure or power supply failure Power LED Off No power Solid Green Normal Solid amber POST is in process Blinking amber Power supply failed MASTER LED Off Switch is in Stacking Slave mode...

Страница 10: ...ble 3 SFP port LEDs LED Description Link LED Off No Link Solid green Link on 10 Gbps speed Solid Amber Link on 1 Gbp speed NOTE If you are using 1x40G one LED displays If you are using 4x10G four LEDs display Activity LED Off No Link Blinking green Transmit receive is active Table 4 QSFP port LEDs LED Description Link LED Off No Link Solid green Link on 40 Gbps speed Solid amber Link on 10 Gbps sp...

Страница 11: ... optional modules and optics separately You can order the following supported hardware components S4048 ON AC Normal Airflow 48 port 10 G RJ 45 ports with six QSFP 40 G ports one AC power supply and three fan subsystems Airflow is from the I O side to the PSU side S4048 ON AC Reverse Airflow 48 port 10 G RJ 45 ports with six QSFP 40 G ports one AC power supply and three fan subsystems Airflow is f...

Страница 12: ...u install your S4048 ON system meets the following safety requirements Near an adequate power source Connect the system to the appropriate branch circuit protection as defined by your local electrical codes Environmental temperature between 32 to 113 F from 0 to 45 C The switch operating ambient temperature range is from 10 to 35 C from 50 to 95 F Operating humidity is from 5 to 85 percent non con...

Страница 13: ...osition the S4048 ON in an equipment rack or cabinet with a minimum of 5 inches 12 7 cm of clearance around the exhaust vents When you install two S4048 ON systems near each other position the two chassis at least 5 inches 12 7 cm apart to permit proper airflow The fan speed increases when the internal temperature reaches 161 6 F 72 C and decreases to normal speed when the temperature falls to 136...

Страница 14: ...st free environment NOTE ESD damage can occur when components are mishandled Always wear an ESD preventive wrist or heel ground strap when handling the S4048 ON and its accessories After you remove the original packaging place the S4048 ON and its components on an anti static surface 14 Site preparations ...

Страница 15: ...connect the system to an external special protection device SPD To be NEBs compliant Locate your system in a restricted access area were only trained personnel are allowed access Install and connect your system to the common bonding network CBN You can also install and connect your system to the central office Connect the battery returns of your system as DC I Ground your system using a copper gro...

Страница 16: ...stallation System power up Unpack the S4048 ON system NOTE Before unpacking the system inspect the container and immediately report any evidence of damage When unpacking the S4048 ON switch make sure that the following items are included One S4048 ON switch One RJ 45 to DB 9 female cable Two sets of rail kits no tools required One PSU a second PSU is sold separately One AC country region specific ...

Страница 17: ...Overloaded power sources and extension cords present fire and shock hazards Elevated ambient temperature If installed in a closed rack assembly the operating temperature of the rack environment may be greater than the room ambient temperature Use care not to exceed the 45 C maximum ambient temperature of the switch Reduced air flow Install the equipment in the rack so that the amount of airflow re...

Страница 18: ...ost flush mount configuration CAUTION Your system is not NEBS Earthquake Z4 compliant if you use this installation method 1 For this configuration remove the latch castings from the front side of each ReadyRails assembly item 1 To remove the two screws from each front flange ear on the switch side of the rail and remove each casting use a Torx screwdriver Retain the castings for future rack requir...

Страница 19: ...ket to the post flange with two user supplied screws Refer to item 3 4 Repeat this procedure for the second rail Two post center mount configuration CAUTION Your system is not NEBS Earthquake Z4 compliant if you use this installation method 1 Slide the plunger bracket rearward until it clicks into place and secure the bracket to the front post flange with two user supplied screws item 1 S4048 ON i...

Страница 20: ...Four post threaded configuration CAUTION To be NEBS Earthquake Z4 compliant you must remove the tool less latch castings described in Step 1 1 For this configuration remove the latch castings from each end of the ReadyRails assemblies To remove the two screws from each flange ear and remove each casting use a Torx driver item 1 Retain the castings for future rack requirements 20 S4048 ON installat...

Страница 21: ...t configurations The following is an example of a front rack configuration For the 1U flush and center two post configurations slide the system into the rails in the same manner as the four post configurations 1U front rack installation You must configure the rails that are attached to the system 1 Attach the inner chassis members switch rails to the S4048 ON system Item 3 shows the detail for the...

Страница 22: ...dy Rails and slide the switch in until it is flush with front of rack About 3 inches before you fully insert your system the rail locking feature engages to keep the switch from inadvertently sliding out of the rack and falling NOTE Do not the use the mounted Ready Rails as a shelf or a workplace 22 S4048 ON installation ...

Страница 23: ...t prior to mating Plated mating surfaces must be clean and free from contamination To connect the ground cable to the system follow these steps 1 Cut the ground cable to the desired length The cable length must facilitate proper operation of the fault interrupt circuits Dell recommends using the shortest cable route allowable 2 Take the one M4x0 7 screw from the package 3 Attach the one hole lug t...

Страница 24: ...n the tab Split QSFP ports to SFP ports The S4048 ON supports splitting a single 40G QSFP port into four 10G ports using one of the supported breakout cables System power up Supply power to the S4048 ON after it is mounted in a rack or cabinet Dell recommends re inspecting your system before powering up Verify the following The equipment is properly secured to the rack and properly grounded option...

Страница 25: ...as the blank plate slot NOTE ESD damage can occur if components are mishandled Always wear an ESD preventive wrist or heel ground strap when handling the S4048 ON and its components CAUTION To prevent electrical shock ensure that the S4048 ON is grounded properly If you do not ground your equipment correctly excessive emissions may result Use a qualified electrician to ensure that the power cables...

Страница 26: ...input of the router AC power supply installation NOTE The PSU slides into the slot smoothly Do not force a PSU into a slot as this action may damage the PSU or the S4048 ON chassis NOTE Ensure that you correctly install the PSU When you install the PSU correctly the power connector is on the right side of the PSU NOTE If you use a single PSU install a blank plate in the other PSU slot If you are o...

Страница 27: ... PSU out of the power supply bay 3 Use the grab handle on the replacement PSU to slide it into the power supply bay 4 Attach the power cord to the replacement PSU NOTE The system powers up when the cables are connected between the power supply and the power source DC power supply installation CAUTION To prevent electrical shock ensure that the S4048 ON is grounded properly If you do not ground you...

Страница 28: ...o that the PSU inserts fully in one orientation only Figure 15 DC PSU installation 1 Orange release tab 2 DC PSU When you install the PSU correctly it snaps into place and is flushed with the back of the switch 4 Plug in the DC power cord from the switch PSU to the external power source 5 If you have a redundant PSU a second PSU repeat steps 1 through 4 using the second PSU slot on the S4048 ON sy...

Страница 29: ...lengths into the wiring block The blue wire is 48V the black wire is the positive return and the yellow green wire is the ground wire as shown 3 Use a flat blade screwdriver to tighten the screws that secures the bare wires into the wiring block 4 Secure the site s DC power source wires to the other side of the wiring block see steps 1 and 3 WARNING Do not cross the wires 5 Insert the DC power con...

Страница 30: ... labels included with the DC power supply kit as shown 2 Locate the regulatory label on the bottom of the switch 3 Attach the DC power label and input rating label over the AC power label and input rating label outlined in red as shown Figure 17 DC power label Figure 18 DC input rating label Figure 19 Switch regulatory label 30 Power supplies ...

Страница 31: ... to the PSU side Reversed airflow is from the PSU side to the I O side All fans and PSUs in a configuration must be in the same airflow direction Environmental factors can decrease the amount of time required between fan replacements Check the environmental factors regularly An increase in temperature and or particulate matter in the air might affect performance for example new equipment installat...

Страница 32: ...g box 2 Use the grab handle to slide the module into the bay Fan module replacement CAUTION Complete steps 2 and 3 within one minute or the system powers down 1 Use the red marked grab handle to slide the fan module out of the bay 2 Use the red marked grab handle on the replacement module to slide it into the bay 3 Ensure that the module is secure After S4048 ON installation After you have securel...

Страница 33: ...on the PC NOTE If your PC s serial port cannot accept a female DB 9 connector acquire a DB 9 male to male adaptor 1 Install the provided RJ 45 connector side of the provided cable into the S4048 ON console port 2 Install the DB 9 female side of the provided copper cable into your PC s serial port or into other data terminal equipment DTE server hardware that you intend to use 3 Keep the default te...

Страница 34: ... your terminal software emulation program to access the S4048 ON 7 Confirm that the terminal settings on your terminal software emulation program are as follows 115200 baud rate No parity 8 data bits 1 stop bit No flow control Mounting the USB Storage The USB storage supports the FAT file system The USB storage does not automatically mount To use USB storage you must first mount the device 1 Creat...

Страница 35: ... if the switch is fully operational before booting After POST the system uses the Grub bootloader Use the up and down arrow keys to select which entry is highlighted Press Enter to select an OS or enter e to edit the commands before booting Enter c for a command line The highlighted entry executes automatically in the operating system Example of the grub bootloader GNU GRUB version 2 02 beta2 e4a1...

Страница 36: ...TP or TFTP using the onie nos install URL command The ONIE Install environment uses DHCP to assign an IP address to the management interface eth0 If that fails it uses the default IP address 192 168 3 10 255 255 255 0 To display the IP address use the ifconfig eth0 command The following is an example of the ifconfig eth0 command ONIE ifconfig eth0 eth0 Link encap Ethernet HWaddr 90 B1 1C F4 9C 76 ...

Страница 37: ...ns Height 1 71 inches 43 5 mm Width 17 09 inches 434 mm Depth 18 11 inches 460 mm Chassis weight with factory installed components 21 7 lbs 9 86 kg Rack clearance required Front 5 inches 12 7 cm Rear 5 inches 12 7 cm Table 6 Environmental parameters Parameter Specifications Operating temperature 32 to 113 F 0 to 45 C Operating humidity 5 to 85 RH non condensing Storage temperature 40 to 158 F 40 t...

Страница 38: ...rotective device SPD at the AC input of the building Use an SPD with the AC power connections to protect the AC power supplies from damage from excessive power line surges In order to comply with the GR 1089 Lightning Criteria for Equipment Interfacing with AC Power Ports use an SPD at the AC input of the router WARNING ESD damage can occur if components are mishandled Always wear an ESD preventiv...

Страница 39: ...Council Directive 2004 108 EC on the approximation of the laws of the Member States relating to electromagnetic compatibility Dell Networking can not accept responsibility for any failure to satisfy the protection requirements resulting from a non recommended modification of this product including the fitting of non Dell Networking option cards This product has been tested and found to comply with...

Страница 40: ...nt VCCI If this equipment is used in a domestic environment radio disturbance may arise When such trouble occurs the user may be required to take corrective actions WARNING Use the AC power cords with Dell Networking equipment only Do not use Dell Force10 AC power cords with any unauthorized hardware Figure 24 Japan Warning Label Korean Certification of Compliance Figure 25 Korean Certification of...

Страница 41: ...Fibre Communication Systems FDA Regulation 21CFR 1040 10 and 1040 11 IEC 60950 1 2nd Ed including all National Deviations and Group Differences Electromagnetic Compatibility EMC Emissions International CISPR 22 2006 Class A Australia New Zealand AS NZS CISPR 22 2009 Class A Canada ICES 003 Issue 4 Class A Europe EN55022 2006 CISPR 22 2006 Class A Japan VCCI V 3 2011 04 Class A USA FCC CFR47 Part 1...

Страница 42: ...s as applicable throughout the European Union This label is applied to various products to indicate that the product is not to be thrown away but rather reclaimed upon end of life per this Directive Figure 27 The European WEEE Symbol In accordance with the European WEEE Directive electrical and electronic equipment EEE is to be collected separately and to be reused recycled or recovered at end of ...

Страница 43: ... Support Services The URL for Dell Support is http www dell com support You must have a user id and password to access Dell Support services If you do not have a user id and password you can request these at the website To request a user id password and Support services follow these steps 1 On the Dell Networking Support page click the Account Request link 2 Fill out the User Account Request form ...

Страница 44: ...w these steps 1 Determine the part number and serial number of the component To list the numbers for all components installed in the chassis use the show hardware command 2 Request an RMA number from TAC by opening a support case Open a support case by Using the Create Service Request form on the iSupport page Contacting Dell Networking directly by email or by phone Provide the following informati...

Отзывы: