Line Card Hardware/Software Requirements

Line Card LED Description

Figure 1-7.  ExaScale 4-port 40G line card

 

NOTE: 

The 4-port 40G line card protrudes from the chassis front by approximately 2 inches. Do not force the 

card flush to the chassis front when installing. The locking levers will secure the card when it is seated in the 
backplane.

 

NOTE: 

The following FTOS features are NOT supported on the 4-port 40G line card (LC-EH-40GE-4P, 
LC-EJ-40GE-4P): Ipv6 MultiCast, Non-default CAM profiles, BFD, PBR, Flow, VLAN Stacking; QOS, CFP 
Optics. Installing the line card in a system running these features can lead to unpredictable behavior.

Table 1-1.  ExaScale Line Card Hardware/Software Requirements

Catalog Number

Description

Hardware Requirements

Minimum FTOS 
Version

10 port 10GE line card with XFP optics (10M 
CAM)

LC-EH-10GE-10P

XFP optics are required

8.3.1.0

10 port 10GE line card with XFP optics (40M 
CAM)

LC-EJ-10GE-10P

XFP optics are required

8.3.1.0

10 port 10GE line card (10M CAM)

LC-EH-10GE-10S

SFP+ optics are required

8.1.1.1

10 port 10GE line card (40M CAM)

LC-EJ-10GE-10S

SFP+ optics are required

8.1.1.1

40 port 10GE line card with SFP+ optics 
(10M CAM)

LC-EH-10GE-40S

SFP+ optics are required

8.3.1.2

40 port 10GE line card with SFP+ optics 
(40M CAM)

LC-EJ-10GE-40S

SFP+ optics are required

8.3.1.2

50 port 1GE line card (10M CAM)

LC-EH-GE-50P

8.3.1.0

50 port 1GE line card (40M CAM)

LC-EJ-GE-50P

8.3.1.0

90 port 1GE line card (10M CAM)

LC-EH-GE-90M

requires MRJ21 cables

8.1.1.2

90 port 1GE line card (40M CAM)

LC-EJ-GE-90M

requires MRJ21 cables

8.1.1.2

Label

Description

Port

L/A:

Blinking Green: Link detected/ Activity

Solid Green: Link detected/ No Activity

Off: No Link/ Card Offline

Status LED

Green: operational

Red: card problem state

Flashing green: booting/ diagnostics

Unlit: in standby mode or power is off

Содержание LC-EJ-10GE-10P

Страница 1: ...le requires at least one line card to operate You can add replace or remove line cards without interrupting the system power or system operations Any line card can be inserted into any line card slot NOTE ExaScale line cards have a minimum FTOS version requirement See Table 1 1 NOTE All chassis slots must be installed with operational modules or blanks Always replace cards and blank panels immedia...

Страница 2: ...m the chassis 6 Align the card with the card slot guides and slide it into the slot until the connectors engage with the chassis backplane Avoid touching the printed circuit board or connector pins 7 Rotate the ejector lever towards the chassis to seat the card into place The card should be flush with the chassis 8 Secure the card in place by tightening the top and bottom captive screws Step Task ...

Страница 3: ...optics 10M CAM LC EH 10GE 10P XFP optics are required 8 3 1 0 10 port 10GE line card with XFP optics 40M CAM LC EJ 10GE 10P XFP optics are required 8 3 1 0 10 port 10GE line card 10M CAM LC EH 10GE 10S SFP optics are required 8 1 1 1 10 port 10GE line card 40M CAM LC EJ 10GE 10S SFP optics are required 8 1 1 1 40 port 10GE line card with SFP optics 10M CAM LC EH 10GE 40S SFP optics are required 8 ...

Страница 4: ...inerate oversubscribes active ports port set number CLI in CONFIGURATION mode The line card must be rebooted when mode or port changes are made Line card boot up may take up to 6 minutes Figure 1 8 ExaScale 90 port 1G line card NOTE 90 port 1G line cards have six port LEDs per input connector one for every physical port Figure 1 9 ExaScale 10 port 10G line card Figure 1 10 ExaScale 50 port 10G lin...

Отзывы: