shows the back panel of the controller with all of the cable connections. See
Controller to a BPS and Power on page 33
for detailed information about the cable connections.
Figure 35: Controller Cable Connections
Table 15: Controller Cable Connections
Number
Description
1
SAN and internal network connections, including the IPMI cable
2
USB connection to BPS
3
Client network connections
4
Power connection to BPS power module
5
Power connection to power source
Routing the Power Cables Through the Strain Relief Straps
The strain relief straps are located on the D-shaped handles on the back of the power supplies. To route the
power cables through the strain relief straps, perform this procedure for each of the power cables on each of the
two controllers:
1. Create a small loop near the end of the power cable where it connects to the controller.
2. Secure the cord to the power supply handle using the strain relief strap. The loop that you created in the
previous step helps provide the strain relief.
shows how to loop the power cables through the strain relief straps.
42
EqualLogic FS7500 Installation and Setup
4 Network Cable Connections
Содержание FS7500
Страница 1: ...EqualLogic FS7500 Installation and Setup ...
Страница 33: ...EqualLogic FS7500 Installation and Setup 2 Hardware Rack Mounting Figure 25 Attaching the Controller Bezel 27 ...
Страница 34: ......
Страница 54: ......
Страница 65: ...EqualLogic FS7500 Installation and Setup 5 NAS Service Configuration Figure 49 NAS Service Status 59 ...
Страница 66: ......
Страница 76: ......
Страница 80: ......
Страница 82: ......
Страница 88: ......