Switch power
To connect the switch to the applicable power source, use the appropriate power cable. An AC power cable is included with
each PSU.
When installing AC or DC switches, follow the code requirements appropriate for your country or region. For example, in the
U.S., follow
National Electrical Code ANSI/NFPA 70
and in Europe follow
IEC60364
.
The switch powers-up when the power cable connects the switch to the power source. For more information, see
.
CAUTION:
To avoid equipment damage, always disconnect the power cables before you service the power supply
slots. The switch has multiple power cables. Before servicing, disconnect all power cables.
CAUTION:
On an AC switch, the main power disconnect device is the power supply cable. Ensure that the socket
outlet is located or installed near the equipment and is easily accessible.
NOTE:
Redundant AC power requires high-line 200 VAC to 240 VAC. Using low-line 120 VAC does not provide redundancy
for the switch.
NOTE:
You do not see module LEDs when the switch powers up in ONIE as the software controls the modules.
Storing components
If you do not install your Z9432F-ON switch and components immediately, properly store the switch and all components using
these guidelines:
●
Storage location temperature must remain constant. The storage range is from -40°C to 70°C (-40° to 158°F).
●
Store on a dry surface or floor, away from direct sunlight, heat, and air conditioning ducts.
●
Store in a dust-free environment.
CAUTION:
ESD damage can occur when components are mishandled. Always wear an ESD-preventive wrist
or heel ground strap when handling the Z9432F-ON switch and accessories. After you remove the original
packaging, place the Z9432F-ON switch and components on an anti-static surface.
14