NOTE:
If the hard drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not
turn on.
NOTE:
Drive status indicator behavior is managed by Storage Spaces Direct. Not all drive status indicators may be used.
Table 22. Hard drive indicator codes
Hard drive status indicator code
Condition
Flashes green twice per second
Identifying drive or preparing for removal.
Off
Drive ready for removal.
NOTE:
The drive status indicator remains off until all drives
are initialized after the system is turned on. Drives are not
ready for removal during this time.
Flashes green, amber, and then turns off
Predicted drive failure.
Flashes amber four times per second
Drive failed.
Flashes green slowly
Drive rebuilding.
Solid green
Drive online.
Flashes green for three seconds, amber for three seconds, and
then turns off after six seconds
Rebuild stopped.
126
Troubleshooting
Содержание D04X
Страница 1: ...Dell Precision 7920 Tower Owner s Manual Regulatory Model D04X Regulatory Type D04X001 ...
Страница 30: ...6 Rotate and lift the fan assembly away from the system 30 Removing and installing components ...
Страница 44: ...4 Slightly slide the panel and lift it away from the chassis 44 Removing and installing components ...
Страница 65: ...Figure 1 Mandatory System Fan Removing and installing components 65 ...
Страница 67: ...Mandatory System Fan Removing and installing components 67 ...
Страница 68: ...68 Removing and installing components ...
Страница 86: ...c Lift and remove the RAID controller battery 86 Removing and installing components ...
Страница 89: ...Installing the VROC module Plug in the VROC module to the system board Removing and installing components 89 ...
Страница 112: ...3 The Bios flash menu will open then click the Flash from file 4 Select external USB device 112 System Setup ...