Troubleshooting
Locate the Service Tag or Express Service Code of
your Dell computer
Your Dell computer is uniquely identified by a Service Tag or Express Service Code. To view relevant support resources for your
Dell computer, we recommend entering the Service Tag or Express Service Code at
.
For more information on how to find the Service Tag for your computer, see
Locate the Service Tag for your Dell Laptop
.
System-diagnostic lights
Power and battery-status light
The power and battery status light indicates the power and battery status of the computer. These are the power states:
Solid white:
Power adapter is connected and the battery has more than 5% charge.
Amber:
Computer is running on battery and the battery has less than 5% charge.
Off:
●
Power adapter is connected, and the battery is fully charged.
●
Computer is running on battery, and the battery has more than 5% charge.
●
Computer is in sleep state, hibernation, or turned off.
The power and battery-status light may also blink red or blue according to pre-defined "beep codes" indicating various failures.
For example, the power and battery-status light blinks red two times followed by a pause, and then blinks blue three times
followed by a pause. This 2,3 pattern continues until the computer is turned off, indicating no memory or RAM is detected.
The following table shows different power and battery-status light patterns and associated problems.
NOTE:
The following diagnostic light codes and recommended solutions are intended for Dell service technicians to
troubleshoot problems. You should only perform troubleshooting and repairs as authorized or directed by the Dell technical
assistance team. Damage due to servicing that is not authorized by Dell is not covered by your warranty.
Table 9. Diagnostic-light LED codes
Diagnostic light codes
(Red, Blue)
Problem description
2,1
Processor failure
2,2
System board: BIOS or ROM (Read-Only
Memory) failure
2,3
No memory or RAM (Random-Access Memory)
detected
2,4
Memory or RAM (Random-Access Memory)
failure
2,5
Invalid memory installed
2,6
System-board or chipset error
2,7
Display failure - SBIOS message
3,1
Coin-cell battery failure
5
Troubleshooting
77
Содержание Alienware x17 R1
Страница 1: ...Alienware x17 R1 Service Manual Regulatory Model P48E Regulatory Type P48E001 June 2021 Rev A01 ...
Страница 13: ...Removing and installing components 13 ...
Страница 14: ...14 Removing and installing components ...
Страница 16: ...16 Removing and installing components ...
Страница 45: ...Removing and installing components 45 ...
Страница 53: ...Removing and installing components 53 ...
Страница 56: ...56 Removing and installing components ...