Microprocessor and Heat Sink
The computer may have up to four microprocessors installed. For more infor-
mation about microprocessors, see “Upgrading the Microprocessor or Installing
Additional Microprocessors” in Chapter 8, “Installing System Board Options”
of the Installation and Troubleshooting Guide.
Figure 4-22. Microprocessor Configuration
1. Remove the support panel and the appropriate microprocessor module.
2. Remove the microprocessor securing clip from the microprocessor/heat
sink assembly.
WARNING: The microprocessor chip can get extremely hot during
system operations. Be sure the chip has had sufficient time to cool
before touching it.
CAUTION: Never remove the heat sink from a microprocessor
unless you intend to remove the microprocessor. The heat sink is nec-
essary to maintain proper thermal conditions.
microprocessor
socket
front tab
clip
thermal pad
(bonded to heat sink)
microprocessor
pin-1 corner of socket
heat sink