4-20
Dell PowerEdge 6100/200 System Service Manual
SIMM
Figure 4-19. Memory Module and SIMM Sockets
SIMMS are located on the memory module that is connected to the system
board. Before you can remove a SIMM, you must remove the support panel and
the memory module from the computer. Place the memory module, component
side up, on an antistatic surface. For more information about SIMMs and the
valid configurations, see “Adding Memory” in Chapter 8, “Installing System
Board Options” of the Installation and Troubleshooting Guide.
Figure 4-20. SIMM Removal
To remove a SIMM, push outward on the SIMM socket’s retaining clips until the
SIMM is released from its socket. Then lift the SIMM away from the socket.
bank 2
J1
bank 1
bank 2
bank 1
J16
J5
J12
1.
retaining clip (2)
2.
SIMM
pin 1