Flag
Number Flag Name
Hex
Code Description
Action Required
Event
25
Interface
19h
Set when the tape drive detects a
problem with the SCSI, Fibre
Channel, or RS-422 interface.
Locate Error Code 8 or 9 in
“Drive Error Codes:
Single-character display (SCD)”
on page 100.
Warning
Event
26
Cooling Fan
Failure
1Ah
A tape drive cooling fan failed.
Fan failure inside tape drive
mechanism or tape drive
enclosure.
Warning
Event
27
Power Supply
1Bh
A redundant power supply failed
inside the tape drive enclosure.
Check the enclosure users
manual for instructions on
replacing the failed power
supply.
A redundant power supply failed
inside the tape drive enclosure.
Check the enclosure users
manual for instructions on
replacing the failed power
supply.
Warning
Event
30
Hardware A
1Eh
Set when a hardware failure
occurs that requires that you reset
the tape drive to recover.
A redundant power supply failed
inside the tape drive enclosure.
Check the enclosure users
manual for instructions on
replacing the failed power
supply.
Warning
Event
31
Hardware B
1Fh
Set when the tape drive fails its
internal Power-On Self-Tests.
Note the error code on the
single-character display and see
in “Drive Error Codes:
Single-character display (SCD)”
on page 100 for the appropriate
instructions.
Warning
Event
32
Interface
20h
Set when the tape drive detects a
problem with the SCSI, Fibre
Channel, or RS-422 interface.
Set when the tape drive detects a
problem with the SCSI, Fibre
Channel, or RS-422 interface.
Warning
Event
33
Eject media
21h
Set when a failure occurs that
requires you to unload the
cartridge from the drive.
Unload the tape cartridge, then
reinsert it and restart the
operation.
Warning
Event
34
Download fail
22h
Set when the tape drive detects a
problem with the SCSI, Fibre
Channel, or RS-422 interface.
Ensure that it is the correct FMR
image. Download the FMR image
again.
Warning
Event
36
Drive temperature 24h
Set when the drive's temperature
sensor indicates that the drive's
temperature is exceeding the
recommended temperature of the
library.
See Error Code 1 in “Drive Error
Codes: Single-character display
(SCD)” on page 100.
Warning
Event
37
Drive voltage
25h
Set when the drive detects that
the externally supplied voltages
are either approaching the
specified voltage limits or are
outside the voltage limits.
See Error Code 2 in “Drive Error
Codes: Single-character display
(SCD)” on page 100.
Warning
Event
38
Predictive failure
26h
A hardware failure of the tape
drive is predicted. Call the tape
drive supplier helpline.
Predictive failure of drive
hardware
Warning
Event
Troubleshooting
99
Содержание 3555-E3A
Страница 1: ...Dell EMC ML3 Tape Library User s Guide ...
Страница 2: ......
Страница 4: ...iv Dell EMC ML3 Tape Library User s Guide ...
Страница 8: ...viii Dell EMC ML3 Tape Library User s Guide ...
Страница 10: ...x Dell EMC ML3 Tape Library User s Guide ...
Страница 20: ...xx Dell EMC ML3 Tape Library User s Guide ...
Страница 22: ...xxii Dell EMC ML3 Tape Library User s Guide ...
Страница 44: ...22 Dell EMC ML3 Tape Library User s Guide ...
Страница 54: ...32 Dell EMC ML3 Tape Library User s Guide ...
Страница 94: ...72 Dell EMC ML3 Tape Library User s Guide ...
Страница 126: ...104 Dell EMC ML3 Tape Library User s Guide ...
Страница 153: ...Figure 81 Unlocked spooling mechanism enlarged view Upgrading and servicing 131 ...
Страница 164: ...142 Dell EMC ML3 Tape Library User s Guide ...
Страница 174: ...152 Dell EMC ML3 Tape Library User s Guide ...
Страница 176: ...154 Dell EMC ML3 Tape Library User s Guide ...
Страница 195: ...XRA External register address register Glossary 173 ...
Страница 196: ...174 Dell EMC ML3 Tape Library User s Guide ...
Страница 200: ...178 Dell EMC ML3 Tape Library User s Guide ...
Страница 201: ......
Страница 202: ...Printed in USA ...