Table 36. Warning events (continued)
Event Code
Message Text and Description
Details and Solution
4127
Drive was restarted because of canister reset. Verify that the drive is installed properly in its
slot and thumb screws are tightened. If the error
persists, replace the drive.
4128
An installed power supply is detected but
does not provide power.
Ensure that the power supply has a power cord
plugged in and is connected to a valid power
source. Although the power source is not
available, this expansion module can still be used
for tape storage. Operation of tape drives is not
possible.
4129
Move from drive failed.
Check backup application how to allow media
removal from drive. If unsuccessful, try the Force
Drive Media Eject
option in the Operations
menu.
4133
Protection Foam not removed from Base
Module
v
Power down the library.
v
Remove top cover and then remove the
protection foam.
v
Install the top cover again and restart the
library.
4135
Drive diagnostic failed
Use another diagnostic tape and run test once
more. If still failing, download drive dumps and
contact service.
4136
The base module detected an installed
power supply but this power supply does
not provide power.
Ensure that the power supply has a power cord
plugged in and is connected to a valid power
source.
4137
Diagnostic Tape not removed.
Open Magazine or I/O station to remove the
diagnostic tape with the OP or Management GUI.
4139
Magazine or I/O Station operation failed.
v
Check whether any obstacle is preventing the
accessor from movement.
v
Restart the library and retry the operation. If
the error persists, replace the accessor
assembly.
v
If the magazine needs to be removed to get
access to the tape cartridges, first power down
the device and then release the magazine
manually. Only one magazine can be open at a
time.
4140
Personality mismatch detected.
Replace either chassis or library controller to
ensure that all parts in the stack are matching the
personality of the main library controller.
4141
Drive requires cleaning.
Clean the drive with an approved cleaning
cartridge.
4142
Medium destination element full.
Ensure that your destination slot or drive is
empty and try again.
4144
Unit to unit lock of lowermost module is
engaged.
Ensure that the alignment mechanism is not
engaged in the lowermost module.
92
Dell EMC ML3 Tape Library: User's Guide
Содержание 3555-E3A
Страница 1: ...Dell EMC ML3 Tape Library User s Guide ...
Страница 2: ......
Страница 4: ...iv Dell EMC ML3 Tape Library User s Guide ...
Страница 8: ...viii Dell EMC ML3 Tape Library User s Guide ...
Страница 10: ...x Dell EMC ML3 Tape Library User s Guide ...
Страница 20: ...xx Dell EMC ML3 Tape Library User s Guide ...
Страница 22: ...xxii Dell EMC ML3 Tape Library User s Guide ...
Страница 44: ...22 Dell EMC ML3 Tape Library User s Guide ...
Страница 54: ...32 Dell EMC ML3 Tape Library User s Guide ...
Страница 94: ...72 Dell EMC ML3 Tape Library User s Guide ...
Страница 126: ...104 Dell EMC ML3 Tape Library User s Guide ...
Страница 153: ...Figure 81 Unlocked spooling mechanism enlarged view Upgrading and servicing 131 ...
Страница 164: ...142 Dell EMC ML3 Tape Library User s Guide ...
Страница 174: ...152 Dell EMC ML3 Tape Library User s Guide ...
Страница 176: ...154 Dell EMC ML3 Tape Library User s Guide ...
Страница 195: ...XRA External register address register Glossary 173 ...
Страница 196: ...174 Dell EMC ML3 Tape Library User s Guide ...
Страница 200: ...178 Dell EMC ML3 Tape Library User s Guide ...
Страница 201: ......
Страница 202: ...Printed in USA ...