Parameter
Specifications
•
5% to 90% (RH), noncondensing short-term (< 1% of
operational hour per year)
Storage temperature
–40°-70°C (–40° to 158°F)
Storage humidity
•
5% to 90% (RH), noncondensing
Maximum operational altitude
3,048 meters (10,000 ft) with no performance degradation to 950
meters (3117 ft)
Maximum nonoperational altitude
10,668 meters (35,000 ft)
Table 7. AC power requirements
Parameter
Specifications
Power supply
100–240 VAC 50/60 Hz
Maximum current draw per system - AC
•
100 VAC: 1.4A
•
240 VAC: 0.6A
Power consumption
Typical:
•
40 W (16 core)
•
35 W (8 core)
•
20 W (4 core)
Maximum:
•
50 W (16 core)
•
45 W (8 core)
•
30 W (4 core)
NOTE:
For the most current AC power requirements and power consumption specifications, see the Installation Guide
at
Safety standards and compliance agency
certifications
•
CUS UL 60950-1, 2nd Edition
•
Meets or exceeds Hi Pot and Ground Continuity testing per UL 60950-1.
•
CSA 60950-1-03, 2nd Edition
•
EN 60950-1, 2nd Edition
•
EN 60825-1, 1st Edition
•
EN 60825-1 Safety of Laser Products—Part 1: Equipment Classification Requirements and User’s Guide
•
EN 60825-2 Safety of Laser Products—Part 2: Safety of Optical Fibre Communication Systems
•
FDA Regulation 21CFR 1040.10 and 1040.11
•
IEC 60950-1, 2nd Ed, including all National Deviations and Group Differences
•
IEC 62368-1
Product recycling and disposal
You must recycle or discard this switch according to applicable local and national regulations. Dell EMC encourages owners of information
technology (IT) equipment to responsibly recycle their equipment when it is no longer needed. Dell EMC offers a variety of product return
programs and services in several countries to assist equipment owners in recycling their IT products.
Waste electrical and electronic equipment (WEEE) directive for recovery, recycle and reuse of IT and telecommunications
products
Specifications
13