Figure 61 Removing an SFP module
EMC3551
Install an SFP module
Procedure
1. Verify that the replacement SFP module has the same part number as the failed
SFP module.
The part number is on a label attached to the SFP module.
2. Push the spring release latch up and slide the new SFP module into the port
until it is securely connected.
Figure 62 Installing an SFP module
EMC3550
3. Push the spring release down to lock the SFP module into place.
4. Reconnect the cable to the replacement SFP module.
Verifying the operation of the new part in Unisphere
Verify that the new part is recognized by your system, and operating correctly.
Procedure
1. In Unisphere, select System View.
2. On the Summary page, confirm that the system status is OK.
3. Select the Enclosures page.
4. Verify that the part appears with the OK status in the enclosure view. You may
need to refresh Unisphere by clicking on the refresh icon next to the
Enclosures view.
If the system health monitor shows the part as faulted, contact your service
provider.
Service Procedures
Install an SFP module
71