Specifications
This section lists the N2200-ON Series switch specifications.
CAUTION:
Operate the product at an ambient temperature not higher than 45°C (113°F).
NOTE:
Restricted Material Compliance
.
Topics:
•
•
•
Chassis physical design
Table 10. Chassis physical design
Parameter
Specifications
Height x Width x Depth measurements, excluding the PSU and fan
tray handle
•
1.71 in x 17 in x 15.75 in (H x W x D)
•
43.5 mm x 434 mm x 400 mm (H x W x D)
(PSU and fan tray handle adds 1.18 in or 30 mm)
Chassis weight with one PSU installed
•
N2224X-ON: 14.30 lbs (6.485 kg)—PSU is 1.75 lbs, 0.79 kg
(550W)
•
N2224PX-ON: 14.70 lbs (6.67 kg)—PSU is 1.95 lbs, 0.88 kg
(1050W)
•
N2248X-ON: 15.09 lbs (6.845 kg)—PSU is 1.75 lbs, 0.79 kg
(550W)
•
N2248PX-ON: 15.77 lbs (7.155 kg)—PSU is 2.0 lbs, 0.90 kg
(1600W)
Rack clearance required
Front: 5 inches (12.7 cm)
Back: 5 inches (12.7 cm)
Table 11. Environmental parameters
Parameter
Specifications
Operating temperature
0° to 45°C (32°F to 113°F) continuously
NOTE:
Reduce maximum temperature by 1°C/125
meters (1°F/228 feet) above 950 meters (3,117 feet).
Operating humidity
5% to 95% (RH), non-condensing
Storage temperature
–40° to 70°C (–40° to 158°F )
Storage humidity
5% to 95%, non-condensing
Maximum thermal output without PoE
•
N2224X-ON: 105 W = 811.58 BTU/hr
•
N2224PX-ON: 115 W = 811.58 BTU/hr
•
N2248X-ON: 160 W = 1111.66 BTU/hr
•
N2248PX-ON: 170 W = 1111.66 BTU/hr
Maximum operational altitude
10,000 feet (3,048 meters)
9
54
Specifications
Содержание PowerSwitch N2200-ON Series
Страница 1: ...Dell EMC PowerSwitch N2200 ON Series Installation Guide...
Страница 16: ...1 Product ID QRL 2 Product information QRL 3 SVC tag 4 MAC address 5 Exp Svc code 16 N2200 ON Series switch...
Страница 44: ...1 Fan N2224X ON fan installation 1 Fan N2248PX ON fan installation 1 Fan N2248X ON fan installation 44 Fans...