5
sled 4
Sled to hard drive mapping
Figure 6. Sled to drive mapping for the enclosure with 24 x 2.5 inch drives
1
drives 0–5 mapped to sled 1
2
drives 6–11 mapped to sled 2
3
drives 12–17 mapped to sled 3
4
drives 18–23 mapped to sled 4
5
(optional) NVMe hard drive location
Figure 7. Sled to drive mapping for the enclosure with 12 x 3.5 inch drives
1
drives 0–2 mapped to sled 1
2
drives 3–5 mapped to sled 2
3
drives 6–8 mapped to sled 3
4
drives 9–11 mapped to sled 4
NOTE:
The warranty of the drives are linked to the Service Tag of the corresponding sled.
Expander zoning
A SAS expander board allows higher, single-volume hard drive configurations. An integrated expander device expands each sleds hard drive
footprint.
The PowerEdge 6400 enclosure allows four sleds to access a single expander controller at the same time. there are two zoning options
available, they are:
•
Up to 6 SAS/SATA device of each sled in Split Mode (6+6+6+6)
PowerEdge C6400 overview
11