background image

Optical transceiver removal and replacement

Disconnect the cable from the SFP+/QSFP optical transceiver.

NOTE: 

Your SFP+/QSFP optical transceivers may differ slightly from the optical transceiver shown in the following 

illustration, but the steps for removal are the same:

Remove the SFP+/QSFP optical transceiver according to the manufacturer’s instructions.

Insert the replacement SFP+/QSFP optical transceiver in the appropriate external port of the switch module.

Figure 7. Optical transceiver removal and replacement

Optical transceiver operation

To verify the transceivers are working correctly, use the following commands:

sfpShow

switchShow

errDump

fabricShow

For a list of output examples and descriptions, see 

Brocade Fabric OS Command Reference

.

Transceiver and cable installation

21

Содержание MXG610s

Страница 1: ...MXG610s Fibre Channel Switch Module Installation Guide May 2018 ...

Страница 2: ... to hardware or loss of data and tells you how to avoid the problem WARNING A WARNING indicates a potential for property damage personal injury or death Copyright 2018 Dell Inc or its subsidiaries All rights reserved Dell EMC and other trademarks are trademarks of Dell Inc or its subsidiaries Other trademarks may be trademarks of their respective owners 2018 05 Rev A00 ...

Страница 3: ...reliability guidelines 12 Static sensitive devices 12 Electrical considerations 13 Environmental considerations 13 Unpack 13 Switch module information 13 4 Switch module installation overview 14 Blade server preparation 14 Switch module installation 14 Switch module replacement 17 5 Transceiver and cable installation 19 Time and items required 19 Transceiver and cable safety consideration 19 Fiber...

Страница 4: ...2 Verify device operation 32 Configuration backup 33 Backup procedure 33 8 Technical specifications 34 System specifications 34 EMC regulatory Compliance 38 Safety regulatory compliance 39 Environmental regulatory compliance 39 9 Regulatory statements 40 Taiwan BSMI statement 40 Canadian requirements 40 CE statement 40 China CCC statement 41 China ROHS 41 Europe and Australia CISPR 32 Class A Warn...

Страница 5: ...aser product tag WARNING When no cable is connected visible and invisible laser radiation may be emitted from the aperture of the optical transceiver ports Avoid exposure to laser radiation and do not stare into open apertures Topics Support hardware and software Document conventions Document feedback Support hardware and software This document is applicable for the following Fibre Channel FC swit...

Страница 6: ...NOTE A Note provides a tip guidance or advice emphasizes important information or provides a reference to related information Attention An Attention statement indicates a stronger note for example to alert you when traffic might be interrupted or the device might reboot CAUTION A Caution statement alerts you to situations that can be potentially hazardous to you or cause damage to hardware firmwar...

Страница 7: ...annel products square brackets may be used instead for this purpose x y A vertical bar separates mutually exclusive elements Nonprinting characters for example passwords are enclosed in angle brackets Repeat the previous element for example member member Indicates a soft line break in command examples If a backslash separates two lines of a command input enter the entire command at the prompt with...

Страница 8: ...single port group when connected to another Dell EMC switch The external ports support dynamic load sharing DLS and dynamic path selection DPS using exchange based balancing when operating as E_Ports Only ISL connections are supported on the QSFP ports Interchassis link ICL connections are not supported on the MXG610s QSFP ports Up to 16 internal backplane FC ports to connect with the FC controlle...

Страница 9: ...ther making port licensing flexible You can upgrade the entry level 8 port and the midlevel 16 port modules with an ENT license that includes ISL trunking fabric vision and extended fabric support Passwords Chassis passwords If a chassis created password applies to your IOMs the instructions included later in this Installation Guide may not function as described Chassis passwords follow this hiera...

Страница 10: ...chassis backplane The switch module seats correctly when the insertion arm is closed Figure 3 Backplane connectors 1 Backplane connectors Module management options To monitor the fabric topology port status physical status and other information use the management functions built into the module Management functions help you analyze switch module performance and accelerate system debugging The devi...

Страница 11: ...ell EMC PowerEdge MX7000 Chassis Management GUI document set Command line interface CLI Brocade Fabric OS Administration Guide Brocade Fabric OS Command Guide Brocade Web tools Brocade Web Tools Administration Guide Standard SNMP applications Fabric OS MIB Reference Management Server Switch module overview 11 ...

Страница 12: ...de server chassis contains either a switch or a filler blade Replace a removed hot swappable switch module with an identical switch module or filler blade within 60 seconds of removal Do not block the ventilation areas on the front and back of the blade server chassis power modules and blowers Follow the reliability guidelines detailed in the blade server chassis documentation Static sensitive dev...

Страница 13: ...ed or restricted Ambient air temperature at the front of the enclosure does not exceed 40ºC 104ºF while the switch module is operating Unpack The shipping carton includes one switch module the blade server FC switch module with two four or eight SWL 32 Gbps SFP transceivers pre installed 1 Open the shipping box and inspect the contents for damage NOTE Do not insert a damaged switch module in the b...

Страница 14: ...you are replacing an existing switch module to maintain the proper cooling level in the chassis insert the replacement switch module within one minute Switch module installation Insert the switch modules in the blade server chassis slots and check that the modules are functioning properly NOTE The switch module works in switch module slots C1 and C2 in the blade server chassis Do not insert the sw...

Страница 15: ...k view with switch module slots marked 1 PowerEdge MX7000 chassis back view 2 Switch module slot C2 3 Switch module slot C1 2 Orient the switch module port side facing you The module latch is on the right side Switch module installation overview 15 ...

Страница 16: ... is steady green for at least two minutes the module is ready to use 4 Start from port 0 then port 17 and then the rest of the ports when cabling the SFP ports If you use QSFP ports instead of SFP ports transfer the port license from port 0 and 17 to the desired QSFP ports The QSFP ports must be unused and no additional port licenses are available Ports 0 and 17 are prelicensed at factory You are ...

Страница 17: ...kes it available for downloading to the replacement switch module if necessary To ensure that a complete configuration is available for downloading to a replacement switch module back up the configuration regularly 2 Stop all activity requiring the ports the switch module uses To verify that there is no activity view the switch module LEDs For details about port management see your blade server ch...

Страница 18: ... airflow and cooling use a filler blade to fill the empty slot Do not leave the slot empty 7 Insert the replacement switch module in the I O module bay of the blade server chassis Complete this step within 60 seconds 8 Insert the SFP or QSFP optical transceivers 9 Reconnect the cables For more information see the SFP or QSFP optical transceivers documentation 10 Establish a connection to the blade...

Страница 19: ...EC 60825 and EN60825 Optical products that do not comply with these standards might emit light that is hazardous to the eyes Transceiver and cable safety consideration To avoid power leakage and equipment safety install the transceivers and cables with care NOTE Use only optical transceivers that are Brocade Communications Systems Inc qualified and comply with the FDA Class 1 radiation performance...

Страница 20: ...e is extended or becomes pinched when the device retracts Route the cable away from places where it may get snagged by other devices in the rack Do not overtighten the cable straps or bend the cables to a radius of less than 5 08 cm 2 in Dell EMC does not recommend tie wraps for optical cables because you can easily overtighten them Do not put excess weight on the cable at the connection point Ens...

Страница 21: ...ptical transceiver according to the manufacturer s instructions 3 Insert the replacement SFP QSFP optical transceiver in the appropriate external port of the switch module Figure 7 Optical transceiver removal and replacement Optical transceiver operation To verify the transceivers are working correctly use the following commands sfpShow switchShow errDump fabricShow For a list of output examples a...

Страница 22: ...3 FC port 24 status LED 4 Module power status LED 5 Module identification LED Table 4 Port side LEDs LED Description Module power and status LED Solid green The switch is working correctly Blinking amber The switch is working incorrectly The temperature may be too high a software error has occurred or another error is discovered Off There is no power supplied to the FC switch module Reseat the mod...

Страница 23: ...For specific information about managing the switch module see the documentation that comes with your blade server chassis To determine whether POST completed successfully or whether any errors were detected Verify that the LEDs on the switch module indicate a healthy switch If one or more LEDs do not display a healthy state verify that the LEDs are not set to beacon To verify the LED state use the...

Страница 24: ...ompted to reboot the switch or to enable the ports 4 Enter the licenseShow command to verify that the license is removed If there are no license keys the command output displays No licenses Software upgrade or downgrade To upgrade the firmware perform the following steps 1 Enter the version command to verify the current firmware version 2 Back up your switch configuration before the firmware downl...

Страница 25: ...ting the switch from the power source can render the switch inoperable and may require you to seek help from your switch service provider 8 Start a separate CLI session on the switch module while the upgrade is proceeding To monitor the upgrade progress use the firmwareDownloadStatus command 9 Enter the version command after the switch module reboots to verify the firmware upgrade Switch module mo...

Страница 26: ...ding subnet mask and gateway address if you did not use DHCP to set the DHCP address Access to an FTP server to back up the switch module configuration Topics Switch module power IP addresses Static IP addresses Serial connection Set date and time Chassis and switch name Set domain ID Software licenses Verify device operation Configuration backup Switch module power The blade server chassis power ...

Страница 27: ...pplication Figure 9 OpenManage Enterprise modular 2 Select Devices I O modules The I O modules display NOTE You may also access the WebTools configuration UI to manage the switch module by typing the switch module IP address into any supported web browser Figure 10 I O modules list 3 Select the I O module name IP address or View Details on the right side of the display The Overview tab is displaye...

Страница 28: ... Apply Figure 13 Management settings 6 Click and expand the Monitoring option Select the Enable SNMP check box the SNMP version and enter a read community string Click Apply Figure 14 Monitoring settings 7 Click and expand the Advanced Settings option Select the needed check boxes 28 Initial setup and verification ...

Страница 29: ...You must disable flow control on the customer side remote terminal server in addition to the host side clients In a UNIX environment using TIP enter tip dev ttyb 9600 at the prompt If you are already using ttyb use ttya instead and enter tip dev ttya 9600 at the prompt 4 Press enter when the terminal emulator application stops reporting information to display the login prompt Switch Console Login ...

Страница 30: ...cifies the minutes Valid values are 00 59 yy Specifies the year Valid values are 00 37 and 70 99 Year values from 70 to 99 are interpreted as 1970 1999 year values from 00 to 37 are interpreted as 2000 2037 device admin date Thu Dec 22 14 05 10 UTC 2016 device admin date 1222140616 Thu Dec 22 14 06 00 UTC 2016 Set time zone The default time zone is Coordinated Universal Time UTC You can only set t...

Страница 31: ...account 2 Change the chassis name using the chassisName command device admin chassisname Chassis_001 3 Change the switch name using the switchName command device admin switchname Switch_001 Committing configuration Done Switch name has been changed Please re login to the switch for the change to applied Set domain ID To set the switch domain ID 1 Log in to the switch through TELNET using the admin...

Страница 32: ...ive switchRole Subordinate switchDomain 70 switchId fffc46 switchWwn 10 00 00 05 1e 65 79 04 zoning ON PERF_CFG switchBeacon OFF FC Router OFF Fabric Name abcfabric Allow XISL Use OFF LS Attributes FID 128 Base Switch No Default Switch Yes Address Mode 0 Index Port Address Media Speed State Proto 0 0 460000 id N32 Online FC F Port 20 05 00 11 0d a8 01 00 1 1 460100 id N32 Online FC F Port 20 01 00...

Страница 33: ...the startup configuration for all switches in the fabric Upload the configuration backup copies to an external host or an attached USB device Avoid copying configuration files from one switch to another Instead restore the switch configuration files from the backup copy Backup procedure To back up the switch module configuration to an FTP server 1 Open a TELNET session to the serial console 2 Ente...

Страница 34: ...back to front port side exhaust System architecture Nonblocking shared memory switch System processors Freescale PowerPC T1022E with two cores at 1 2 GHz Table 7 Fibre Channel specifications System components Description Fibre Channel ports Default switch mode 16 external ports supporting 8 Gbps 16 Gbps and 32 Gbps speeds using eight SFPs and two QSFPs 16 internal ports supporting 16 Gbps and 32 G...

Страница 35: ...ack Enabled on all ports APC policy default Disabled Group policy default Enabled ADS policy default Disabled Preferred secondary failover None specified Table 10 Default access gateway mode port mapping Internal port F_port Server port External port N_port Fabric port HBA Mezzanine Port 1 0 Lane 0 of Server Sled 1 2 17 Lane 0 of Server Sled 2 3 18 Lane 0 of Server Sled 3 4 19 Lane 0 of Server Sle...

Страница 36: ...cal dimension Height Width Depth Weight empty Weight fully loaded 75 cm 1 08 in 21 45 cm 8 44 in 24 10 cm 9 49 in 1 35 kg 2 98 lb 1 61 kg 3 55 lb Table 14 Environmental requirements Condition Operational Storage Ambient temperature 5 C to 50 C 23 F to 122 F 40 C to 70 C 40 F to 158 F Relative humidity noncondensing 5 to 95 5 to 95 Non condensing Altitude above sea level Up to 3200 m 10 000 feet 0 ...

Страница 37: ...ransceivers Can be F_Port N_Port or E_Port 24 through 31 4x16 or 4x32 Gbps QSFP ports Compatible with SWL and LWL transceivers Can be F_Port N_Port or E_Port Table 17 Fibre Channel data transmission ranges Port speed Gbps Cable size microns Short wavelength SWL Long wavelength LWL Extended long wavelength ELWL 8 50 50 m 164 ft OM2 150 m 492 ft OM3 190 m 623 ft OM4 N A N A 62 5 21 m 69 ft N A N A 9...

Страница 38: ...ry Type Size Main memory DDR3L SDRAM with 8 bit ECC SORDIMM package operating at 1200 MT s 2 GB 64 bit Boot flash Parallel NOR flash embedded memory 16 MB eUSB module 2 GB Table 21 Support for extended fabrics distances SFP and QSFP Minimum distance Maximum distance ELWL 10 km 6 21 miles 3000 km 1864 11 miles EMC regulatory Compliance FCC Part 15 Subpart B EN 55024 EM 55032 CE Mark Class A ICES 00...

Страница 39: ... EU 2006 66 EC batteries and accumulators and waste batteries and accumulators EU battery directive 1907 2006 of the European Parliament and of the Council of 18 December 2006 concerning the Registration Evaluation Authorisation and Restriction of Chemicals EU REACH Section 1502 of the Dodd Frank Wall Street Reform and Consumer Protection Act of 2010 U S Conflict Minerals 30 2011 TT BCT Vietnam ci...

Страница 40: ...anadian Interference Causing Equipment Regulations ICES 003 Class A Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada CE statement NOTE This product is a Class A In a domestic environment this product might cause radio interference You might be required to take corrective measures The standards compliance label on this device contains the CE mark that indicates this s...

Страница 41: ...t revision of the China ROHS document P N 53 1000428 xx that ships with the product Europe and Australia CISPR 32 Class A Warning This product is a Class A In a domestic environment this product may cause radio interference You may be required to take adequate measures Regulatory statements 41 ...

Страница 42: ...residential area is likely to cause harmful interference in which case you are required to correct the interference at the user s own expense Germany statement Machine noise information regulation 3 GPSGV the highest sound pressure level value is 48 5 dB A in accordance with EN ISO 7779 Maschinenlärminformations Verordnung 3 GPSGV der höchste Schalldruckpegel beträgt 48 5 dB A gemäss EN ISO 7779 R...

Страница 43: ...ommage conservez les appareils sensibles à l électricité statique dans leur emballage protecteur tant qu ils n ont pas été installés PRECAUCIÓN La electricidad estática puede dañar el chasis y otros dispositivos electrónicos A fin de impedir que se produzcan daños conserve los dispositivos susceptibles de dañarse con la electricidad estática dentro de los paquetes protectores hasta que esté listo ...

Страница 44: ... in 21 CFR Unterkapitel I sowie IEC 60825 und EN60825 erfüllen Optische Produkte die diese Normen nicht erfüllen können Strahlen aussenden die für das menschliche Auge gefährlich sind DANGER Utilisez uniquement des émetteurs récepteurs optiques certifiés par Brocade Communications Systems Inc et conformes aux exigences sur la puissance de rayonnement de catégorie 1 de la FDA définies au sous chapi...

Страница 45: ... down to the bottom of the web page and select your country from the drop down menu To obtain product specific information enter the 7 character service tag known as a luggage tag or 11 digit express service code of your switch and click Submit To view the chassis service tag or express service code pull out the tag or enter the show chassis command from the CLI To receive more technical support c...

Отзывы: