Figure 13 Sliding server into of the cabinet
Connect power cords and I/O cables
Procedure
1. Using the connection information recorded on the labels, connect the I/O
cables to the server.
The following table lists the connections between the Dell server iDRAC ports
and the Dell switch.
Table 10 iDRAC ports and Dell switch connections
Server
iDRAC port connection
Power EdgeR630 1
Dell switch port 37
Power EdgeR630 2
Dell switch port 36
Power EdgeR630 3
Dell switch port 35
Note
The lower row of Ethernet ports is not directly below the top row as shown in
the table. The first and third ports from the left on both rows are cabled to the
Dell switch.
The following table lists the connections between the Dell server I/O ports and
the Dell Switch.
Table 11 Ethernet port layouts
Server
I/O port connections
Power EdgeR630 1
Dell switch port 10
Dell switch port 12
Dell switch port 9
Dell switch port 11
Power EdgeR630 2
Dell switch port 6
Dell switch port 8
Dell switch port 5
Dell switch port 7
Power EdgeR630 3
Dell switch port 2
Dell switch port 4
Dell switch port 1
Dell switch port 3
2. Plug the power cords into the power supplies.
Dell PowerEdge R630 Server FRUs
DELL EMC CONFIDENTIAL
56
Integrated Data Protection Appliance (IDPA)
2.1
Field Replacement Guide