Table 1 IDPA component replacement shutdown requirements (continued)
Model
Component
shutdown is not
required
Component
shutdown is
required
Data Domain ES30/FS15
l
3.5" disk drive
l
Bezel
l
LCC
l
Power/cooling
module
l
Chassis
l
Rails
Avamar Gen4T server
l
3.5" disk drive
l
Network switch
l
Power supply
l
2.5" solid state
drive
l
Chassis
l
DIMM
l
Fan
l
I/O module
l
SP
Dell PowerEdge R630 server
l
Disk drive
l
Power supply
l
Server chassis
Not applicable
Dell S4048-ON Ethernet switch
l
Power supply
l
Fan
l
SFP
Complete switch
replacement
Replacing a component of the Dell PowerEdge server requires that you connect to the
Dell switch to access the VMware vSphere web Client, and the Dell server iDRAC
interface. Connect to port 38 on the Dell switch. The switch port layout is displayed in
the following table.
Table 2 Switch port layout
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
Identify the IDPA
The Data Domain system has an IDPA-specific serial number on its Product Serial
Number Tag (PSNT). Before beginning any replacement activities on the IDPA, verify
that the PSNT information on the Service Request matches the PSNT information on
the Data Domain system.
Prepare the Integrated Data Protection Appliance for Hardware Replacement
DELL EMC CONFIDENTIAL
Identify the IDPA
13