Back panel
The back panel has two dual power supplies and two LCCs (Link Controller Cards).
Figure 4 DS60 back panel
Each controller has 4 SAS ports (laid out as 2 pairs). Standard Data Domain systems,
and systems with the licensed HA feature only use ports 0 and 2 on each controller.
Ports 1 and 3 typically have a plastic plug blocking the unused ports to make inserting
a cable into the correct ports easier.
Note
on page 17 chapter for details about cabling.
on page 24 section provides the needed details.
Table 7 Status lights visible from rear of disk enclosure
Light
Quantity
Color
Meaning
Controller
power
1 per controller Green
On when the Controller is powered on.
Controller fault
1 per controller Amber
On when either the Controller or a SAS
connection is faulty. On during power-on
self test.
Link active
4 per controller Blue
On when the host connection is active.
Power supply
input voltage
1 per power
supply
Green
Input power green when it is working.
Power supply
fault*
1 per power
supply
Amber
l
On when the power supply is faulty or
is not receiving AC line voltage.
l
Flashing when either a multiple blower
or ambient over temperature condition
has shut off DC power to the system.
The DS60 continues to run with a single power supply and two fans (out of the three
fans).
For part replacement information, refer to the
DS60 Installation and FRU Replacement
Guide.
DS60 Shelf Installation Overview
16
Data Domain DS60 Expansion Shelf
Hardware Guide
Содержание Data Domain DS60
Страница 1: ...Dell EMC Data Domain DS60 Expansion Shelf Hardware Guide 302 002 100 REV 05 ...
Страница 4: ...Hardware specifications 100 CONTENTS 4 Data Domain DS60 Expansion Shelf Hardware Guide ...
Страница 8: ...Revision history 8 Data Domain DS60 Expansion Shelf Hardware Guide ...
Страница 31: ...Figure 9 Recommended cabling for DD4500 3TB drives Installing the Shelves DD4200 DD4500 and DD7200 cabling 31 ...
Страница 43: ...Figure 19 DD6300 Installing the Shelves DD6300 DD6800 and DD9300 cabling 43 ...
Страница 45: ...Figure 21 DD6800 and DD9300 with HA Installing the Shelves DD6300 DD6800 and DD9300 cabling 45 ...
Страница 46: ...Figure 22 DD6800 with DD Cloud Tier Installing the Shelves 46 Data Domain DS60 Expansion Shelf Hardware Guide ...
Страница 47: ...Figure 23 DD6800 with HA and DD Cloud Tier Installing the Shelves DD6300 DD6800 and DD9300 cabling 47 ...
Страница 53: ...Figure 27 Cabling for HA DD9500 and DD9800systems Installing the Shelves DD9500 and DD9800 cabling 53 ...
Страница 80: ...Installing the Shelves 80 Data Domain DS60 Expansion Shelf Hardware Guide ...
Страница 98: ...Post Installation Tasks 98 Data Domain DS60 Expansion Shelf Hardware Guide ...