Table 9. DD6800 with ES30 primary node cabling instructions (continued)
String
(Loop)
I/O - Port
Shelf Port
Length
2
I/O 2 - Port 2
A controller HOST
port of the highest number shelf in V2
2M
3
I/O 7 - Port 1
B controller HOST
port of shelf V3.1
2M
3
I/O 2 - Port 1
A controller HOST
port of the highest number shelf in V3
2M
4
I/O 7 - Port 3
B controller HOST
port of shelf V4.1
3M
4
I/O 2 - Port 3
A controller HOST
port of the highest number shelf in V4
3M
a.
Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be used.
Table 10. DD6800 with ES30 standby node cabling instructions
String
(Loop)
I/O - Port
Shelf Port
Length
1
I/O 7 - Port 0
A controller EXPANSION
port of shelf V1.1
2M
1
I/O 2 - Port 0
B controller EXPANSION
port of the highest number shelf in V1
2M
2
I/O 7 - Port 2
A controller EXPANSION
port of shelf V2.1
2M
2
I/O 2 - Port 2
B controller EXPANSION
port of the highest number shelf in V2
2M
3
I/O 7 - Port 1
A controller EXPANSION
port of shelf V3.1
2M
3
I/O 2 - Port 1
B controller EXPANSION
port of the highest number shelf in V3
2M
4
I/O 7 - Port 3
A controller EXPANSION
port of shelf V4.1
3M
4
I/O 2 - Port 3
B controller EXPANSION
port of the highest number shelf in V4
3M
a.
Cable lengths shown are designed for Data Domain racks. Longer cables (up to 5M) can be used.
52
Connect Cables and Power On