![Deligreen BI51 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/deligreen/bi51/bi51_user-manual_2467272010.webp)
.
BI51 Type User Manual V2.4
9
Figure 3 System wiring diagram
Notice: BIU have to be installed into the negative side of battery pack when using BIU +BMU
combination. e.g: when using BM5116 to collect a 32 cells pack, the cell of total negative is
B1,the cell of total positive is B32.Then BI5116 should collect B1~B16,and BM5116 should collect
B17~B32.It’s very important to connect correctly, or the total voltage and insulation detection will be
influenced.
2.3 System parameters
Table 3 System parameters
Parameter
Min
Typical
Max
Unit
Description
Detection range of
total voltage
12
\
600
V
12~300V, rated voltage of battery pack
Detection accuracy
of total voltage
\
\
\
%
≤
0.2%
Total voltage
detection channel
\
\
2
\
Two channels of relay could be used at same
time.
Series of battery
4
\
160
S
BIU can collect 48s at most; BMU qty can be
extended to 10.units.