PLASTIC LAMINATE

In most cases, you only need to use a clean, damp nonabrasive 

cotton cloth and a mild liquid detergent or household cleaner.  Rinse 

with clean water, using a clean, nonabrasive cotton cloth.  Do not 

flood the laminate, especially near seams since water can penetrate 

and cause the substrate to swell.  Dry the surface with a soft, clean, 

non-abrasive cotton cloth.

DO NOT use abrasive cleaners, powders, steel wool, sandpaper, 

or Scotch-Brite™ scouring pads.  Use a trivet, insulated hot pad or 

other protective device beneath all hot cookware, heat generating 

appliances, or other heated objects.

CORIAN

®

There are three types of countertop finishes: matte, 

semigloss and gloss.  All Corian

®

 sinks and bowls 

have the matte finish.  Soapy water or ammonia-based 

cleaners will remove most dirt and stains from all 

types of finishes.  However, slightly different techniques must be 

used to remove difficult stains, depending on the finish.

Preventing Heat Damage: 

to prevent heat damage, always use a hot 

pad or a trivet with rubber feet to protect your Corian.

Daily cleaning of the interior and exterior of the unit is recommended. 

All food must be removed from the interior before cleaning. Always 

wear gloves and eye protection when handling cleaning solutions and 

cleaning the salad bar.

GLASS:

 Use the mildest cleaning product available to clean glass 

mirrors on the salad bar. Typically, soap and water, or ammonia will 

clean the glass sufficiently. If stronger solutions are required, be 

sure to use products designed for use on glass. Cleaning products 

designed for other materials will leave residue that is not removable. 

DISINFECTING: 

If the interior surface requires disinfecting, use a 

product that contains Alkyl Ammonium Chloride to kill germs.

GREASE REMOVAL: 

Your regular daily cleaner may not remove 

grease, fingerprints or other oily deposits found on glass.  In this 

case, use a stronger degreasing cleaner with butoxyethanol. Apply 

this cleaner with sponge or cloth.  Remove with a squeegee.  Reclean 

as necessary if streaks appear from degreaser.

DEGREASERS CAN HARM YOU. ALWAYS WEAR PROTECTIVE 

GLOVES AND EYE PROTECTION WHEN USING THESE MATERIALS.

CLEANING REFRIGERATED PLATFORM

: After removing all food 

product and containers, lift the platform by grasping the front edge 

and pulling up.

When lifting front edge take caution to ensure palms are down as 

to not pinch fingers.  See Figure-1 and Figure-2.

The platform is mounted on two pistons, located at 

each end of the platform. Once raised, clean food debris 

from the area, paying attention not to force food down 

the drain of this area. 

This drain is easily clogged and 

difficult to clean.

 Once food debris is cleaned out of the 

area, use soap and water to wash the area and rinse. This will flow 

down the drain. When cleaning is done, pull the platform down. 

CABINET WOOD

To clean, gently wipe liquid spills up with a damp towel.  If necessary 

use with mild detergent.

CLEANING INSTRUCTIONS

CAUTION

Figure-1

Figure-2

Содержание Nordic Zone Cold Food Bars

Страница 1: ...Manual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 August 2003 IMPORTANT INFORMATIO...

Страница 2: ...re should be taken during unloading so the equipment is not damaged while being moved into the building 1 Visually inspect the unit Any damage should be noted and reported to the delivering carrier im...

Страница 3: ...ied It may be necessary to trim pieces slightly to fit REFRIGERATION INSTALLATION If the condensing units are to be set on the roof of the building it must be mounted on beams supplied by the roofing...

Страница 4: ...ning product available to clean glass mirrors on the salad bar Typically soap and water or ammonia will clean the glass sufficiently If stronger solutions are required be sure to use products designed...

Страница 5: ...change the setting of the defrost timer or thermostat Adjustments are to be made by qualified service technicians only Defrost cycles are factory preset and should not require field adjustments In th...

Страница 6: ...USE IKTK R 5 BLACK BLACK BLUE BLACK BLUE 120v TO 24v TRANSFORMER HEATING ELEMENTS GREEN END LAMP WHITE BLACK LAMP 1 LAMP 2 Y Y R R B B R B B Y Y R BALLAST 120v INPUT 227v OUTPUT GREEN WHITE BLACK RAIL...

Страница 7: ...URE LIGHT ON OFF SWITCH NEUTRAL L1 GND WHITE RED BLUE XF FUSE OFNM 15 X1 X2 RED WHITE BLACK HF FUSE IKTK R 5 H4 H2 H3 H1 H1 FUSE IKTK R 5 BLACK BLACK BLUE BLACK BLUE 120v TO 24v TRANSFORMER HEATING EL...

Страница 8: ...e 3516173 Fan guard 2162691 Fan motor ONE SIDE OF THE 123 Remote PART NUMBER DESCRIPTION 323457 Control knob ring guard 2194620 Fan safety switch RTP00013 34 Fluorescent bulb RTP00034 UCM 8 Fluorescen...

Страница 9: ...Nordic Zone Salad Bar Service and Installation Manual 9 For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com FULL VIEW 207 Switch and defrost locations...

Страница 10: ...rdic Zone Salad Bar Service and Installation Manual For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 10 FULL VIEW 123 10 35 10 35 135 32 3 22 20 20 123 5 83 5 102...

Страница 11: ...AMINATE FRONT CLEAR TEMPERED GLASS SNEEZE GUARD LAMINATE TOP 1 CHROME HINGE 1 2 GLASS STOP POWDER COATED ARM LAMINATE END REAR SPLINE DETAIL 18 SPLINE TOP LAMINATE FRONT 1 S S SEAMS REAR OF UPPER STRU...

Страница 12: ...Nordic Zone Salad Bar Service and Installation Manual For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 12 NSF Official Listing For Lighting System...

Страница 13: ...REPLACE Thermostat Contactor Relay Infinite Switch Transformer Door Jamb Switch Evaporator Condenser Fan Motor and Blade Solenoid Coil Circulating Fan Motor and Blade Hi limit Thermal Protector Switch...

Страница 14: ...PLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE If shipment of a replacement part is requested prior to the arrival in the Delfield factory...

Страница 15: ...altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was originally installed The addition of methyl chloride to th...

Страница 16: ...Nordic Zone Salad Bar Service and Installation Manual For customer service call 800 733 8829 800 773 8821 Fax 989 773 3210 www delfield com 16 NOTES...

Страница 17: ...272 7358 fax serves AR LA NM OK TX 7 Stove Parts Supply GCS Service 9923 S W 178th St Vashon WA 98070 888 872 2465 206 463 1772 206 463 4431 FAX serves AK HI ID MT OR WA 12 Performance Refrigeration...

Отзывы: