Section 2
Installation
Part Number: 9291545 REV00 11/20 9
Electrical Service
DANGER
Check all wiring connections, including factory terminals,
before operation. Connections can become loose during
shipment and installation.
n
Warning
This appliance must be grounded and all field wiring must
conform to all applicable local and national codes. Refer
to rating plate for proper voltage. It is the responsibility of
the end user to provide the disconnect means to satisfy
the authority having jurisdiction.
Voltage
All electrical work, including wire routing and grounding,
must conform to local, state and national electrical codes.
The following precautions must be observed:
• The equipment must be grounded.
• A separate fuse/circuit breaker must be provided for each
unit.
• Check all green ground screws, cables and wire
connections to verify they are tight before start-up.
Ground Fault Circuit Interrupter
Ground Fault Circuit Interrupter (GFCI/GFI) protection is a
system that shuts down the electric circuit (opens it) when it
senses an unexpected loss of power, presumably to ground.
Welbilt does not recommend the use of GFCI/GFI circuit
protection to energize our equipment. If code requires the
use of a GFCI/GFI then you must follow the local code. The
circuit must be dedicated, sized properly and there must
be a panel GFCI/GFI breaker. We do not recommend the
use of GFCI/GFI outlets to energize our equipment as they
are known for more intermittent nuisance trips than panel
breakers.
Custom Model
Amps
H.P. Rail & Base / Catch Pan
Volts/Hertz/Phase
Plug
F18DC48P-RCPR
8.4
.35 / .20
115/60/1
5-15P
F18DC48P-RCPL
8.4
.35 / .20
115/60/1
5-15P
F18DC72P-RCPR
8.4
.35 / .20
115/60/1
5-15P
F18DC72P-RCPL
8.4
.35 / .20
115/60/1
5-15P
F18DC99P-RCPR
8.8
.35 / .25
115/60/1
5-15P
F18DC99P-RCPL
8.8
.35 / .25
115/60/1
5-15P
.20H.P. = 1/5H.P. .25H.P. = 1/4H.P. .35H.P. = 1/3H.P.