Dual View Series Service and Installation Manual
3
Delfield
™
®
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
Location
These units are intended for indoor use only. Be sure the
location chosen has a floor strong enough to support 1000
pounds of the cabinet and contents. Reinforce the floor as
necessary to provide for maximum loading.
For the most efficient refrigeration, be sure to provide good
air circulation inside and out.
Inside cabinet
: Do not pack refrigerator so full that air
cannot circulate.
Outside cabinet
: Be sure that the unit has access to ample
air. Avoid hot corners and locations near stoves and ovens.
Leveling
A level cabinet looks better and will perform better because:
1. The drain pan will drain properly.
2. The doors will line up with the frames properly.
3. The cabinet will not be subject to undue strain.
To meet NSF standards, this unit must be sealed to the
floor.
Installation of glass shelves
1. Remove stainless steel shelf bracket assemblies by
sliding key slots over shoulder bolts on inside edges of
posts.
2. Plug light cords into receptacles.
3. Place 0.25” safety glass shelves on brackets.
Installation of dry section front & side glass
1. Remove (2) acorn nuts on bottom side of shelf.
2. Remove top of stainless steel shelf by lifting shelf off
subtop.
3. Place 0.25” thick side glass pieces into bottom channel
and lower rear of stainless steel shelf.
4. Place 0.25” thick front glass piece into bottom channel
and lower front of stainless steel shelf over top edge of
glass.
5. Replace acorn nuts on bottom side of shelf.
Plumbing
Self-contained models are standard with a condensate
evaporator. If the evaporator fails, the unit’s drain must have
an outlet to an appropriate drainage area or container.
Moisture collecting from improper drainage
can create a slippery surface on the floor
and a hazard to employees. It is the owner’s
responsibility to provide a container or outlet for
drainage.
Electrical connection
Refer to the wattage data on page 2, the serial tag and your
local code to be sure the unit is connected to the proper
power source. A protected circuit of the correct voltage
and amperage must run for connection of the line cord, or
permanent connection to the unit.
Self-contained units have an ON/OFF switch located in the base
of the unit. Simply turn the switch to ON to begin operation.
The power switch must be turned OFF and
the unit disconnected from the power source
whenever performing service or maintenance
functions.
CAUTION
On self-contained models, after turning the ON/OFF switch
to ON, the unit’s compressor will begin operating. Delfield
display cases are designed to maintain an operation
temperature of 36°F to 40°F at ambient room temperature of
75°F and relative humidity of 55%.
Do not load the storage area in a way that restricts the air
flow. Overloading will result in a loss of temperature.
Continuous opening and closing of the doors will hamper
the units ability to maintain operational temperature.
Installation
Operation Information
Shelves
Front
Sides
(Top)
34.0” x 15.84”
(Center)
34.0” x 17.24”
(Bottom)
32.50” x 15.43”
24.95” x 35.0”
Two Each Required:
24.57” tall;
19.38” at bottom
15.04” at top
*** All glass shelving is .25” thick safety glass.***
Display Case Glass Replacement
Delfield professionally packages the glass in the crate
to minimize the risk of freight damage. However, during
shipment glass damage can happen and breakage is not
covered under warranty. If your Delfield unit arrives with
broken glass in the top dry section, we recommend that you
purchase replacement glass locally. The table to the right lists
replacement sizes for the dry top section only.
Please call your Delfield service or sales representative if you
have any questions on glass replacement.