background image

Thank you for choosing Delfield!

Help is a phone call away.  Help our team of professional, courteous 

customer service reps by having your model number and serial number 

available at the time of your call (800) 733-8829.

Model: ____________________ S/N:  ___________________

Installation Date: ____________

For a list of Delfield’s authorized parts depots, 

visit our website at www.delfield.com.

Mt. Pleasant, MI

Covington, TN

980 S. Isabella Rd., Mt. Pleasant, MI  48858, U.S.A. • (989) 773-7981 or (800) 733-8829 • Fax (989) 773-3210 • www.delfield.com

Delfield reserves the right to make changes in design or specifications without prior notice.  ©2008 The Delfield Company.  All rights reserved. Printed in the U.S.A.

DMDUAL 06/08

Содержание Dual View 536-SR68

Страница 1: ...ual Please read this manual completely before attempting to install or operate this equipment Notify carrier of damage Inspect all components immediately See page 2 536 SR68 Effective Date June 2008 IMPORTANT INFORMATION READ BEFORE USE PLEASE SAVE THESE INSTRUCTIONS Delfield ...

Страница 2: ...ion 2 Receiving and Inspecting the Equipment 2 Specifications 2 Installation 3 Operation 3 Display Case Glass Replacement 3 Maintenance 4 Pressure Control Settings 5 Wiring Diagram 5 Replacement Parts Lists 6 Standard Warranties 7 9 Contents Serial Number Location Receiving And Inspecting The Equipment Even though most equipment is shipped crated care should be taken during unloading so the equipm...

Страница 3: ... from improper drainage can create a slippery surface on the floor and a hazard to employees It is the owner s responsibility to provide a container or outlet for drainage Electrical connection Refer to the wattage data on page 2 the serial tag and your local code to be sure the unit is connected to the proper power source A protected circuit of the correct voltage and amperage must run for connec...

Страница 4: ...inless steel breakdown are small pits and cracks If this has begun clean thoroughly and start to apply stainless steel cleaners in attempt to restore the passivity of the steel Never use an acid based cleaning solution Many food products have an acidic content which can deteriorate the finish Be sure to clean the stainless steel surfaces of ALL food products Common items include tomatoes peppers a...

Страница 5: ...ed models was adjusted at the factory to maintain between 36 F and 40 F No adjustment should be necessary If adjustment does become needed however the factory recommended settings are Operating pressure 80 psi cut in 50 psi cut out 30 psi differential 536 SR68 L1 S1 S2 PS1 CONDENSING UNIT COOLING FANS CONDENSATE EVAPORATOR BALLAST BALLAST BALLAST Remote Units Only FLUORESCENT LIGHTS G N If your De...

Страница 6: ...bracket 264 052 Z000D Dry 24 95 x 35 00 glass front 3455355 Dry 24 75 x 19 38 glass side 3455357 Dry door plate mount LT 264 AYK Z000E Dry door plate mount RT 264 AYK Z000F Evaporator coil 3510086 Evaporator fan motor 2162691 Expansion valve 3516273 Fan motor blower coil bracket 031 264 0000 Filter dryer 3516101 Glass shelf 15 43 x 32 50 3544342 Glass shelf bottom dry 3455341 Glass shelf top dry 3...

Страница 7: ...ess pre approved with a Service Work Authorization from Delfield You must submit the number with the service claim LABOR OF 1 HOUR IS ALLOWED TO REPLACE Circulating Fan Motor and Blade Compressor Start Components and Overload Protector Condensate Element Door Hinges Locks and Gaskets Evaporator Condenser Fan Motor and Blade LABOR OF 2 HOURS TO REPLACE Heating Element Locate Repair Leak Pressure Co...

Страница 8: ...PPLICABLE TIME AND MATERIALS RATES CONSIDER CUSTOMER MAY INITIATE A SERVICE AGREEMENT WITHOUT PARTS COVERAGE If shipment of a replacement part is requested prior to the arrival in the Delfield factory of the part claimed to be defective the Original Purchaser must accept delivery of the replacement part of a C O D basis with credit being issued after the part has been received and inspected at Del...

Страница 9: ...en altered defaced or removed This Warranty does not apply to a Motor Compressor in any Unit that has been moved from the location where it was originally installed The addition of methyl chloride to the condensing unit or refrigeration system shall void this warranty General Conditions Delfield shall not be liable in any manner for any default or delay in performance hereunder caused by or result...

Страница 10: ...Dual View Series Service and Installation Manual 10 Delfield For customer service call 800 733 8829 800 733 8821 Fax 989 773 3210 www delfield com Notes ...

Страница 11: ...Dual View Series Service and Installation Manual 11 Delfield For customer service call 800 733 8829 800 733 8821 Fax 989 773 3210 www delfield com notes ...

Страница 12: ...____________________ Installation Date _____________ For a list of Delfield s authorized parts depots visit our website at www delfield com Mt Pleasant MI Covington TN 980 S Isabella Rd Mt Pleasant MI 48858 U S A 989 773 7981 or 800 733 8829 Fax 989 773 3210 www delfield com Delfield reserves the right to make changes in design or specifications without prior notice 2008 The Delfield Company All r...