background image

 

 
 
 
 
 
 
 
 
 
 
 
 

DelfiScan M80 

Programming Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание DelfiScan M80

Страница 1: ...DelfiScan M80 Programming Manual...

Страница 2: ...o reproduce and transmit this documentation for the purchaser s own internal business purposes Purchaser shall not remove or alter any proprietary notices including copyright notices contained in this...

Страница 3: ......

Страница 4: ...ut 28 Serial Trigger Lock 28 Keyboard Nationality 29 Fifo 29 Inter character Delay 30 Inter code Delay 31 Control Character Emulation 31 USB Keyboard Speed 32 WEDGE PARAMETERS 33 Keyboard Nationality...

Страница 5: ...Timeout 61 Flash Mode 62 Reads per Cycle 62 Safety Time 63 Beeper Intensity 63 Beeper Tone 64 Beeper Type 64 Beeper Length 64 Stand Recognition Beep 65 DECODING PARAMETERS 66 Ink Spread 67 Overflow C...

Страница 6: ...l Timeout 110 Power Off Timeout 110 Beeper Control for Radio Response 111 Single Store 112 Batch Mode 112 4 REFERENCES 114 5 TECHNICAL FEATURES 136 A HOST CONFIGURATION STRINGS 141 B CODE IDENTIFIER T...

Страница 7: ...vi GENERAL VIEW DELFISCAN M80 READERS Reading Window Trigger Cradle Locking System Latch Charge completed yellow LED Charging red LED...

Страница 8: ...nuous and multi tasking activities are keys to optimum productivity lower cost of ownership and profitable business 1 1 READING ANGLE DelfiScan M80 readers automatically scan barcodes at a distance Si...

Страница 9: ...DELFISCAN M80 2 1 2 HANDS FREE USE When using the DelfiScan M80 on the cradle remember to lock the reader by pushing up the locking system as indicated in the following figure...

Страница 10: ...before using the reader in hand held mode NOTE In hands free use you can immediately start using the reader since it is powered by the cradle 3 Configure the DelfiScan M80 reader 4 Configure the Delfi...

Страница 11: ...Figure 4 Do not incinerate disassemble short terminals or expose to high temperature Risk of fire explosion Use specified charger only Risk of explosion if the battery is replaced by an incorrect typ...

Страница 12: ...rface type 1 Connect the appropriate interface cable to the cradle by simply plugging it into the Host connector on the base of the cradle DelfiScan M80 Cradle Bottom View To disconnect the cable inse...

Страница 13: ...DELFISCAN M80 6 2 4 RS 232 CONNECTION 2 5 USB 2 6 IBM USB POS 2 7 WEDGE CONNECTION only for DelfiScan M80 Type 130 CAB 413 CAB 391 or CAB 321 CAB 431 CAB 431 POWER SUPPLY ADAPTER...

Страница 14: ...INSTALLATION 7 2 8 PEN EMULATION CONNECTION 2 9 SINGLE READER LAYOUT...

Страница 15: ...ble at the top of each page of configuration 3 Modify the desired parameters in one or more sections following the procedures given for each group 4 Read the Exit and Save Configuration code ONCE avai...

Страница 16: ...low to set the radio address of the DelfiScan M80 reader Enter configuration 3 Set Radio Address RA0RFH four digits for the DelfiScan M80 Address from 0000 to 1999 All readers used in the same area mu...

Страница 17: ...DELFISCAN M80 10 7 Read the cradle restore default code Restore cradle default RX0 q Go to par 3 3 Interface Selection Yellow LED...

Страница 18: ...3 INTERFACE SELECTION Read the interface selection code for your application RS 232 Standard CP0 POS Terminals Nixdorf Mode A CM2EC0 Fujitsu CM1 ICL Mode CM0 For POS terminal default settings refer to...

Страница 19: ...DELFISCAN M80 12 WEDGE only for DelfiScan M80 Type 130 IBM AT or PS 2 PCs CP500 a IBM XT CP503 v PC Notebook CP505 IBM SURE1 CP506 IBM Terminal 3153 CP504...

Страница 20: ...the interface for these IBM Terminals read the correct KEY TRANSMISSION code Select the KEYBOARD TYPE if necessary default advanced keyboard KEY TRANSMISSION MODE make only keyboard CP502 o make break...

Страница 21: ...ently from the Keyboard Nationality used You do not need to make a Keyboard Nationality selection default Num Lock Unchanged Make sure the Num Lock key on your keyboard is ON IBM AT ALT mode CP507 PC...

Страница 22: ...CONFIGURATION 15 WEDGE CONTINUED DIGITAL TERMINALS VT2xx VT3xx VT4xx CP512 u...

Страница 23: ...the start up phase ends correctly the yellow LED stops blinking In rare cases if the Host does not supply sufficient power to the reader a dialog box will appear on the Host and the reader will be blo...

Страница 24: ...SB KBD APPLE UA05 F USB COM UA02 4 USB IBM Table Top UA00 USB IBM Hand Held UA01 When configuring USB COM the relevant files and drivers must be installed from the USB Device Installation software whi...

Страница 25: ...iScan M80 type 130 PEN EMULATION The following parameter groups are common to all interface applications DATA FORMAT parameters regard the messages sent to the Host system for all interfaces except Pe...

Страница 26: ...R DELAY RX TIMEOUT SERIAL TRIGGER LOCK 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Read the code and follow the proced...

Страница 27: ...Enter Configuration Exit and Save Configuration RS 232 20 BAUD RATE 300 baud CD1X 600 baud 1200 baud CD2 CD3 2400 baud 4800 baud CD4a CD5d 9600 baud 19200 baud CD6g CD7j 38400 baud CD8m...

Страница 28: ...Enter Configuration Exit and Save Configuration RS 232 21 PARITY none CC0S even parity CC1V odd parity CC2Y DATA BITS 7 bits CA0O 8 bits CA1R 9 bits CA2U STOP BITS 1 stop bit CB0Q 2 stop bits CB1T...

Страница 29: ...E0W hardware RTS CTS CE1Z software XON XOFF CE2 RTS always ON CE3 See par 4 1 1 for details ACK NACK PROTOCOL disable ER0s enable ER1v See par 4 1 2 for details particularly on implementing this param...

Страница 30: ...ed to Host CK3 Read 2 numbers from the table where 00 DELAY disabled 01 99 DELAY from 1 to 99 milliseconds delay disabled RX TIMEOUT timeout control in reception from Host CL5 Read 2 numbers from the...

Страница 31: ...RIAL TRIGGER LOCK disabled CR0q enable and select characters CR1t Read 2 characters from the Hex Numeric table in the range 00 FE where First Character enables device trigger Second Character inhibits...

Страница 32: ...nter code delay Control character emulation USB keyboard speed USB IBM No parameter selection required 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration c...

Страница 33: ...USB COM 26 HANDSHAKING disable CE0W hardware RTS CTS CE1Z software XON XOFF CE2 RTS always ON CE3 See par 4 1 1 for details ACK NACK PROTOCOL disable ER0s enable ER1v See par 4 1 2 for details FIFO di...

Страница 34: ...n Exit and Save Configuration USB COM 27 INTER CHARACTER DELAY delay between characters transmitted to Host CK3 Read 2 numbers from the table where 00 DELAY disabled 01 99 DELAY from 1 to 99 milliseco...

Страница 35: ...UT disabled 01 99 TIMEOUT from 1 to 9 9 seconds rx timeout 5 seconds See par 4 1 4 for details SERIAL TRIGGER LOCK disabled CR0q enable and select characters CR1t Read 2 characters from the Hex Numeri...

Страница 36: ...USB KBD ALT MODE Interface This parameter default value is restored through the Interface Selection code and not Restore Default Belgian FJ7y English French FJ4p FJ2j German Italian FJ3m FJ1g Japanes...

Страница 37: ...n Exit and Save Configuration USB KBD 30 INTER CHARACTER DELAY delay between characters transmitted to Host CK3 Read 2 numbers from the table where 00 DELAY disabled 01 99 DELAY from 1 to 99 milliseco...

Страница 38: ...ration USB KBD 31 INTER CODE DELAY delay between codes transmitted to Host FG Read 2 numbers from the table where 00 DELAY disabled 01 99 DELAY from 1 to 99 seconds delay disabled CONTROL CHARACTER EM...

Страница 39: ...Enter Configuration Exit and Save Configuration USB KBD 32 USB KEYBOARD SPEED Normal UT10c Fast UT01d...

Страница 40: ...DELAY KEYBOARD SETTING CONTROL CHARACTER EMULATION 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Read the code and foll...

Страница 41: ...nfiguration WEDGE 34 KEYBOARD NATIONALITY Belgian FJ7y English French FJ4p FJ2j German Italian FJ3m FJ1g Spanish Swedish FJ6v FJ5s USA FJ0d The Japanese Keyboard Nationality selection is valid only fo...

Страница 42: ...to match your keyboard caps lock status Note Caps lock manual configuration is ignored when Caps Lock Auto Recognition is enabled For PC Notebook interface selections the caps lock status is automati...

Страница 43: ...ormally on use num lock unchanged if your keyboard Num Lock is normally off use toggle num lock In this way the device will execute the Alt Mode procedure correctly for your application INTER CHARACTE...

Страница 44: ...essed and released key must generate an acoustic signal on the reader otherwise repress the key Never press more than one key at the same time even if this corresponds to the normal use of your keyboa...

Страница 45: ...nderscore 23 2 46 I 69 24 3 47 J 70 25 4 48 K 71 26 5 49 L 72 27 6 50 M 73 74 DEL The keyboard setup functioning is signaled by the LEDs on the cradle Each key stroke corresponds to a double blinking...

Страница 46: ...Enter Configuration Exit and Save Configuration WEDGE 39 CONTROL CHARACTER EMULATION CTRL Shift Key FO0n CTRL Key FO1q...

Страница 47: ...OVERFLOW OUTPUT LEVEL IDLE LEVEL INTER BLOCK DELAY 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Default value 3 Read t...

Страница 48: ...e complete commands and do not require reading the Enter and Exit configuration codes OPERATING MODE interpret mode 8 Interprets commands without sending them to the decoder transparent mode 4 Sends c...

Страница 49: ...n Exit and Save Configuration PEN EMULATION 42 MINIMUM OUTPUT PULSE 200 s low resolutioncode emulation highresolution code emulation DG0 400 s 600 s DG1_ DG2b 800 s 1 ms DG3e DG4h 1 2 ms DG5k See par...

Страница 50: ...TO CODE 39 AND CODE 128 disable conversion to Code 39 DA0P Transmits codes in their original format enable conversion to Code 39 DA1S Converts codes read into Code 39 format enable conversion to Code...

Страница 51: ...Exit and Save Configuration PEN EMULATION 44 OVERFLOW narrow DH0 medium DH1a wide DH2d See par 4 2 3 for details OUTPUT LEVEL normal white logic level 0 DD0V inverted white logic level 1 DD1Y See par...

Страница 52: ...normal black level DE0X inverted white level DE1 See par 4 2 4 for details INTER BLOCK DELAY delay between character blocks transmitted to Host CK3 Read 2 numbers from the table where 00 DELAY disable...

Страница 53: ...ER CODE LENGTH TX CHARACTER REPLACEMENT ADDRESS STAMPING ADDRESS DELIMITER 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups...

Страница 54: ...13 with 5 ADD ON E 2 M UPC A with 2 ADD ON X y F UPC A with 5 ADD ON X y G UPC E with 2 ADD ON X y H UPC E with 5 ADD ON X y I Code 39 A y V Code 39 Full ASCII A y W CODABAR F y R ABC CODABAR X y S Co...

Страница 55: ...igit tx or not etc When customizing the Datalogic Standard code identifiers 1 or 2 identifier characters can be defined for each code type If only 1 identifier character is required the second charact...

Страница 56: ...Enter Configuration Exit and Save Configuration DATA FORMAT 49 CODE IDENTIFIER disable EB0S Datalogic standard EB1V AIM standard EB2Y custom EB3...

Страница 57: ...You can define 1 or 2 identifier characters for each code type If only 1 identifier character is required the second character must be selected as FF disabled Read the hexadecimal value corresponding...

Страница 58: ...cter header six character header EA05 EA06B seven character header eight character header EA07F EA08J After selecting one of the desired Header codes read the character s from the HEX table Valid char...

Страница 59: ...aracter terminator six character terminator EA15A EA16E seven character terminator eight character terminator EA17I EA18M After selecting one of the desired Header codes read the character s from the...

Страница 60: ...Wedge IBM AT PS 2 and USB KBD Interfaces It is necessary to define each Special Key by following the procedure given in par 4 2 7 NOTE Select one or more of the following Special Keys according to yo...

Страница 61: ...tion right deletion 12 23 left deletion 34 f Read a number in the range 01 32 from the Hex Numeric Table to define how many characters to add or delete Conditions Adjustment is only performed on the b...

Страница 62: ...E For Wedge and USB KBD interfaces it is also possible to read the Special Key s on page 53 Example To define the field adjustment character A field adjustment character CODE LENGTH TX code length not...

Страница 63: ...dix B read the Code Identifier for the desired code family 0 character replacement will be effective for all code families e From the Hex Numeric Table read two characters corresponding to the Hex val...

Страница 64: ...character first character replacement Code 39 ASCII characters corresponding to the HEX value for character 0 ASCII characters corresponding to the HEX value for character 1 EO1p VW 30 31 For Code 39...

Страница 65: ...ing RU0 enable reader address stamping RU1 See par 4 2 8 for details ADDRESS DELIMITER disable reader address delimiter RV0 enable reader address delimiter and select characters RV1 Read 2 HEX charact...

Страница 66: ...PER INTENSITY BEEPER TONE BEEPER TYPE BEEPER LENGTH STAND RECOGNITION BEEP 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups...

Страница 67: ...rigger BK1e software trigger always on BK0b BK3k automatic not available for Mobile series readers hardware trigger ready BK2h BK4n STAND OPERATION ONLY Devices with Stand Recognition Beep hardware tr...

Страница 68: ...r active pulse BA1Q See par 4 3 1 for details TRIGGER OFF TIMEOUT trigger off timeout BD Read 2 numbers in the range 00 99 00 disables the trigger off timeout 01 99 corresponds to a max 99 sec delay a...

Страница 69: ...ETERS 62 FLASH MODE FLASH ON duration BB0P FLASH OFF duration BB1S Read 2 numbers in the range 01 99 01 to 99 from 1 to 9 9 seconds Flash ON 1 sec Flash OFF 0 6 sec READS PER CYCLE one read per cycle...

Страница 70: ...at least 400 ms 01 99 timeout from 1 to 9 9 seconds before a consecutive read on same code safety time 0 5 sec See par 4 3 4 for details BEEPER INTENSITY very low intensity BG0Z low intensity medium i...

Страница 71: ...Enter Configuration Exit and Save Configuration READING PARAMETERS 64 BEEPER TONE tone 1 BH0 tone 2 tone 3 BH1_ BH2b tone 4 BH3e BEEPER TYPE monotone BJ0 bitonal BJ1c BEEPER LENGTH long BI0 short BI1a...

Страница 72: ...Enter Configuration Exit and Save Configuration READING PARAMETERS 65 STAND RECOGNITION BEEP ONLY Devices with Stand Recognition disable BV0x enable BV1...

Страница 73: ...efore changing these parameter values read the descriptions in par 4 4 CAUTION 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired gr...

Страница 74: ...Enter Configuration Exit and Save Configuration DECODING PARAMETERS 67 INK SPREAD disable AX0 enable AX1 See par 4 4 1 for details OVERFLOW CONTROL disable AW1 enable AW0y See par 4 4 2 for details...

Страница 75: ...DECODING PARAMETERS 68 INTERDIGIT CONTROL disable AV0w enable AV1z See par 4 4 3 for details DECODING SAFETY one read ED0W decoding safety disabled two reads three reads ED1Z ED2 four reads ED3 Requi...

Страница 76: ...read codes using this technology simply move the illuminated bar over the code so that each line of the code is scanned During this process a series of brief ticks indicates that reading is proceeding...

Страница 77: ...N DELTA IBM CODE 11 CODE 16K CODE 49 GS1 DATABAR 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Read the code and follow...

Страница 78: ...it the number of CODES enabled to 5 as it depends on the code family NOTE SINGLE SELECTIONS Example 5 code selections 1 2 5 Interleaved 2 2 5 Industrial 3 Code 128 EAN 128 4 Code 39 Full ASCII Code 32...

Страница 79: ...ILY disable the family AA0M c Read the desired family code Note Since the EAN UPC without ADD ON code selection is enabled by default to correctly enable another selection first disable the family WIT...

Страница 80: ...d Save Configuration CODE SELECTION 73 WITH ADD ON 2 AND 5 EAN 8 EAN 13 UPC A UPC E AA5 EAN 8 EAN 13 AA6_ UPC A UPC E AA7b WITH ADD ON 2 ONLY EAN 8 EAN 13 AAK7 UPC A UPC E AAM WITH ADD ON 5 ONLY EAN 8...

Страница 81: ...nd without ADD ON no Autodiscrimination AA8Ad03 EAN UPC Autodiscrimination ADD ON by Prefix AA8Ad19 By setting the EAN UPC Autodiscrimination ADD ON by Prefix the desired prefixes must be selected by...

Страница 82: ...the barcode will not be read Barcodes starting with different characters are read regardless of ADD ON presence and transmitted always without ADD ON NOTE Cancel All Selections ET0w OR select one or m...

Страница 83: ...and transmission with ADD ON of all EAN UPC barcodes starting with 434 439 prefixes 3 977 enables reading and transmission with ADD ON of all EAN UPC barcodes starting with 977 prefix 4 978 enables re...

Страница 84: ...AN UPC CHECK DIGIT TX SELECTIONS For each code type in this family you can choose to transmit the check digit or not CHECK DIGIT TRANSMISSION EAN 8 NO CHECK DIGIT TRANSMISSION AAG1o EAN 8 AAG0k EAN 13...

Страница 85: ...13 conversion AAC EAN 8 to EAN 13 conversion AAD Enable only ISBN conversion AP1n Enable only ISSN conversion AP2q Enable both ISBN and ISSN conversion AP3t Disable both ISBN and ISSN conversion AP0k...

Страница 86: ...de below is part of the 2 5 family but has no check digit or code length selections The maximum code length is 99 characters The minimum code length must always be less than or equal to the maximum Co...

Страница 87: ...AB4 Italian pharmaceutical code CODE LENGTH optional The code length selection is valid for the entire Code 39 family Read the code 4 numbers for the code length where set code length First 2 digits m...

Страница 88: ...parate a variable length code field from the next code field This character can also be transmitted before the code disable EQ0q enable EQ1t If the GS character has been modified in the Character Repl...

Страница 89: ...ode length is 99 characters The minimum code length must always be less than or equal to the maximum Examples 0199 variable from 1 to 99 digits in the code 1010 10 digit code length only The length is...

Страница 90: ...mission selection START STOP CHARACTER TRANSMISSION Standard Codabar AD113 no start stop character equality control no transmission 12 Standard Codabar AD127 start stop character equality control tran...

Страница 91: ...ength where set code length First 2 digits minimum code length Second 2 digits maximum code length AD A The maximum code length is 99 characters The minimum code length must always be less than or equ...

Страница 92: ...10 check digit control check digit transmission AE3 MOD11 MOD10 check digit control no check digit transmission AE4a MOD11 MOD10 check digit control check digit transmission AE5d MOD10 MOD10 check dig...

Страница 93: ...ECTION 86 check digit control check digit transmitted AF12 check digit control check digit not transmitted AF13 Anker Plessey no check digit control AF21 check digit control check digit transmitted AF...

Страница 94: ...f the check digit selections Numeric Telepen no check digit control AL11C check digit control check digit transmitted AL12G check digit control check digit not transmitted AL13K Alphanumeric Telepen n...

Страница 95: ...nd Save Configuration CODE SELECTION 88 DELTA IBM disable the family AH0 Enable the code by selecting one of the check digit selections no check digit control AH1 Type 1 check digit control AH2a Type...

Страница 96: ...ol AG1 Type C check digit control check digit transmitted AG21 Type C check digit control check digit not transmitted AG22 Type K check digit control check digit transmitted AG31 Type K check digit co...

Страница 97: ...e so that each line of the code is scanned During this process a series of brief ticks indicates that reading is proceeding correctly CODE 49 disable the code AM0e Code 49 AM1h To read stacked codes s...

Страница 98: ...10I enable RSS Expanded Linear and Stacked disable RSS Limited AQ11M AQ20L enable RSS Limited disable RSS 14 Linear and Stacked AQ21P AQ30O enable RSS 14 Linear and Stacked AQ31S To read stacked codes...

Страница 99: ...tting parameters may not be compatible with the IBM USB POS interface selection NOTE 1 Read the Enter Configuration code ONCE available at the top of page 2 Read configuration codes precisely followin...

Страница 100: ...ype and length It is possible to set a timeout for the second code reading and to define code transmission if the timeout expires The order of transmission is CODE 1 CODE 2 Define Concatenation 1 Code...

Страница 101: ...g code The Code ID character will be sent in the output message only if it is enabled according to the Code Identifier selection Datalogic AIM or Custom 4 Concatenation Timeout timeout EJ3 Read two nu...

Страница 102: ...Exit and Save Configuration ADVANCED FORMATTING 95 only code 2 transmitted if read after timeout EM2o either code 1 or code 2 transmitted after timeout EM3r...

Страница 103: ...s can be defined and saved in memory For each format you must complete the entire configuration procedure Define another Enable Advanced Formats 1 2 3 4 Define No Match Result Read the Exit and Save C...

Страница 104: ...1W begin Format 3 definition HA2Z begin Format 4 definition HA3 2 Match Code Type match code type HB Read the above code the code type to match from the Code Identifier Table in Appendix B OR any code...

Страница 105: ...Example Match code with the 2 character predefined string Read Match with a 2 character string 40 40 AND position of first character in predefined string HE Read the above code two numbers in the rang...

Страница 106: ...as the last character of the field OR BY b defining a match character to be found consecutively repeated in the code itself In this case the field ends with the first character that does not match OR...

Страница 107: ...om the HEX table Range of characters 01 FE OR field length c HG1c Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length d HG2f AND Field 1 Termina...

Страница 108: ...om the HEX table Range of characters 01 FE OR field length c HG1c Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length d HG2f AND Field 2 Termina...

Страница 109: ...om the HEX table Range of characters 01 FE OR field length c HG1c Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length d HG2f AND Field 3 Termina...

Страница 110: ...om the HEX table Range of characters 01 FE OR field length c HG1c Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length d HG2f AND Field 4 Termina...

Страница 111: ...om the HEX table Range of characters 01 FE OR field length c HG1c Read two numbers in the range 01 to 99 to define the field length OR this is the last field variable length d HG2f AND Field 5 Termina...

Страница 112: ...fixed field HI5s 6 character fixed field HI6v After selecting one of the Additional Fixed Field codes read the corresponding character s from the HEX table Range of characters 01 FE For Wedge and USB...

Страница 113: ...rfaces it is also possible to read the Special Key s on page 53 Example 3 Character Fixed Field 53 45 54 SET 9 Field Transmission number of fields to transmit HK8 Read one number in the range 1 to 7 f...

Страница 114: ...nsmit 4 Field 2 Additional Field 1 Field 1 Field 2 10 Standard Formatting do not apply standard formatting HL0j apply standard formatting HL1m After performing Advanced Formatting on the barcode read...

Страница 115: ...sable HN30P Advanced Format 4 enable HN41W disable HN40S No Match Result clear data no transmission HO0p transmit data using standard format HO1s This selection determines the action to be taken when...

Страница 116: ...RESPONSE SINGLE STORE BATCH MODE 1 Read the Enter Configuration code ONCE available at the top of each page 2 Read configuration codes from the desired groups Read the code and follow the procedure gi...

Страница 117: ...number from the table where 02 19 timeout from 2 to 19 seconds 2 seconds See par 4 5 1 for details POWER OFF TIMEOUT power off timeout RPL Read 2 numbers in the range 00 99 00 Power off disabled read...

Страница 118: ...Enter Configuration Exit and Save Configuration RADIO PARAMETERS 111 BEEPER CONTROL FOR RADIO RESPONSE normal BF0X only good decode only good reception BF1 BF2 off BF3a See par 4 5 3 for details...

Страница 119: ...RE disable RO0z one attempt two attempts RO1 RO2 three attempts four attempts RO3 RO4 five attempts six attempts RO5 RO6 seven attempts eight attempts RO7 RO8 nine attempts RO9 See par 4 5 4 for detai...

Страница 120: ...n RADIO PARAMETERS 113 BZ2 See par 4 5 5 for details The following batch management parameters are complete commands and do not require reading the Enter and Exit configuration codes start normal batc...

Страница 121: ...e Host is active RTS Transmitted data Transmitted data TX CTS Host busy Signals at EIA levels RTS CTS handshaking Software handshaking XON XOFF During transmission if the Host sends the XOFF character...

Страница 122: ...s default setting to Normal see par 4 5 3 When ACK NACK is disabled there is no control from cradle to Host transmission the reader responds with the good reception tone Host data cable QuickScan Mobi...

Страница 123: ...an error and discards any further codes until the transmission is restored If the FIFO buffering is disabled each code must be transmitted before another one can be read If enabled the cradle collects...

Страница 124: ...utput pulse corresponding to the narrowest element in the barcode In this way the code resolution is controlled by the signal sent to the decoder independently of the physical resolution of the code r...

Страница 125: ...imes the minimum output pulse 4 2 4 Output and Idle Levels The following state diagrams describe the different output and idle level combinations for Pen emulation bar space white black barcode output...

Страница 126: ...4 2 5 Inter Block Delay For the PEN Emulation interface data are sent to the Host in fixed size blocks of 20 characters each The inter block delay parameter allows setting a delay between each block s...

Страница 127: ...Message from DelfiScan M80 STAR System Towards Host Header Code ID Code Length CODE Terminator Items in square brackets are optional 4 2 6 Header Terminator Selection The header terminator selection i...

Страница 128: ...10 F10 F10 8F F11 ESC F11 F11 90 F12 BACKSPACE F12 F12 91 HOME HOME ENTER F13 92 END END RESET F14 93 PG UP PG UP INSERT F15 94 PG DOWN PG DOWN DELETE F16 95 FIELD UP 96 FIELD DOWN 97 ENTER Paddle LEF...

Страница 129: ...cial Keys can be used for Headers Terminators Character Replacement Field Adjustment Custom Code ID Advanced Formatting Define Field Advanced Formatting Additional Fixed Field Follow the procedure to...

Страница 130: ...Exit and Save Configuration 123 2 Read only one code to be associated with the special key sequence SHIFT 12 OR CTRL 23 OR ALT 45 OR CTRL SHIFT 34 OR ALT SHIFT 56 OR CTRL ALT 67...

Страница 131: ...S 025 S 025 S 025 A 025 S 02E S 02E S 052 S 052 S 02E S 02E S 02E S 02E S 02E S 036 S 03D S 016 016 036 S 03D S 036 S 036 S 036 S 04E 052 025 025 05D S 052 04E 05D 03D S 03E S 046 S 02E 02E 03E S 046...

Страница 132: ...024 024 024 024 f 02B 02B 02B 02B 02B 02B 02B 02B 02B g 034 034 034 034 034 034 034 034 034 h 033 033 033 033 033 033 033 033 033 i 043 043 043 043 043 043 043 043 043 j 03B 03B 03B 03B 03B 03B 03B 03...

Страница 133: ...0A F9 001 001 001 001 001 001 001 001 001 F10 009 009 009 009 009 009 009 009 009 F11 078 078 078 078 078 078 078 078 078 F12 007 007 007 007 007 007 007 007 007 Home 26C 26C 26C 26C 26C 26C 26C 26C 2...

Страница 134: ...al Key Sequences 1 the following example allows defining Special Key 1 as SHIFT F5 enter configuration define Special Key 1 SHIFT Read FQ9C2 12 codes from Appendix C corresponding to the character val...

Страница 135: ...racter value for F1 exit save configuration 005 Integrating Special Keys in Headers Terminators 1 the following example allows setting Special Key 1 defined in example 1 above as terminator enter conf...

Страница 136: ...Address Stamping parameter consists of a 4 digit number in the range 0000 1999 For message output format refer to par 0 4 2 9 Address Delimiter The Address Delimiter allows a character to be included...

Страница 137: ...ally after the desired period of time 4 3 3 Reads per Cycle In general a reading cycle corresponds to the ON OFF times of a device The resulting effects of this parameter on code reading depend on oth...

Страница 138: ...reader for particular applications Used incorrectly they can degrade the reading performance or increase the possibility of a decoding error CAUTION 4 4 1 Ink Spread The ink spread parameter allows th...

Страница 139: ...l the reader returns to the standard mode If transmission is not successful after the number of configured attempts the code is discarded Single store may be useful if you often read codes at the limi...

Страница 140: ...Data barcode allows canceling all barcode data stored in the reader Automatic batch mode allows codes to be stored in the reader on a FIFO basis whenever the reader is out of radio range In this case...

Страница 141: ...or default settings K Transmit the reader Software release _ Transmit the reader configuration in ASCII format This command is not effective with Pen emulation interface or with the reader model RX0 q...

Страница 142: ...r Custom Custom Custom Header No Header No Header No Header Terminator CR CR CR Field Adjustment Disabled Disabled Disabled Code Length TX Not Transmitted Not Transmitted Not Transmitted Character Rep...

Страница 143: ...1 Reading field see reading diagram Max resolution 0 10 mm 4 mils PCS minimum 20 Delfi Test Chart Environmental Features READER Working Temperature 0 to 40 C 32 to 104 F Storage Temperature without ba...

Страница 144: ...7 DelfiScan M80 Radio Features Radio Features European Models USA Models Radio Frequency 433 92 MHz 910 MHz Bit rate 19200 baud 36800 baud Effective Radiated Power 10 mW 1 mW Range in open air 12 m 12...

Страница 145: ...6 5 2 STATUS INDICATORS The reader has a LED indicator and a Beeper The cradle has three LEDs They signal several operating conditions which are described in the tables below H high tone L low tone RE...

Страница 146: ...y to be inserted into the cradle L Success H L long tones Failure 1 Only the Beeper Intensity command can modify these signals 2 The data entry good read tone is user configurable with all the Beeper...

Страница 147: ...5 3 READING DIAGRAMS DELFISCAN M80 Readingdiagram at 25 C and3 00lux ambie nt lighting Reading Zones 10 skewangle 0 5 10 15 20 25 30 1 0 5 0 5 10 cm EAN13M 1 0 33mm 13 mils CODE39 0 50 mm 20mils 0 13...

Страница 148: ...x Exit and save new configuration AC410132 BH0 Matrix 2 5 3 bars no check digit variable length code from 1 to 32 characters Enter configuration environment Multiple command programming sequence Each...

Страница 149: ...e Terminal ANSI Keyboard CP509 for Wyse Terminal PC Keyboard CP510 for Wyse Terminal ASCII Keyboard CP511 for Wyse Terminal VT220 style Keyboard CP514 for Digital Terminals VT2xx 3xx 4xx CP512 for App...

Страница 150: ...ial Trigger Lock disable CR0 enable CR1ab USB KBD Keyboard nationality Belgian FJ7 not for USB KBD ALT MODE English FJ4 French FJ2 German FJ3 Italian FJ1 Japanese FJ8 Spanish FJ6 Swedish FJ5 USA FJ0 F...

Страница 151: ...FO0 CTRL Key FO1 PEN DESCRIPTION STRING Operating mode interpret does not require or transparent does not require or Minimum output pulse 200 s DG0 400 s DG1 600 s DG2 800 s DG3 1 ms DG4 1 2 ms DG5 C...

Страница 152: ...EA18xxxxxxxx Special Keys special key 1 9C special key 2 9D special key 3 9E special key 4 9F special key 5 A0 a ASCII character b c x HEX values representing an ASCII character a ASCII character of...

Страница 153: ...elimiter and select character RV1h a ASCII character d a number from the Hex Numeric Table e f g h HEX values representing an ASCII character a ASCII character of the DATALOGIC STANDARD Code Identifie...

Страница 154: ...ode trigger active level BA0 trigger active pulse BA1 Trigger off Timeout s BD00 BD99 FLASH ON 100 ms BB001 BB099 FLASH OFF 100 ms BB101 BB199 Reads per Cycle one read BC0 multiple reads BC1 Safety Ti...

Страница 155: ...ON 2 ONLY AAM with ADD ON 5 ONLY AAN with ADD ON 2 AND 5 AA7 EAN UPC with and without Add On no Autodiscrimination AA8Ad0 EAN UPC Autodiscrimination Add On by Prefix AA8Ad1 Select Prefixes cancel all...

Страница 156: ...AC21xxxx check digit control and transmission AC22xxxx check digit control without transmission AC23xxxx Industrial 2 5 IATA no check digit control AC31xxxx check digit control and transmission AC32x...

Страница 157: ...Q0 enable EQ1 ISBT 128 enable ISBT 128 AI31 code length AILxxxx Code 93 disable Code 93 family AK0 enable Code 93 control without transmission of check digit AK1 MSI disable the family AE0 no check AE...

Страница 158: ...AG0 no check AG1 Type C with tx AG21 Type C no tx AG22 Type K with tx AG31 Type K no tx AG32 Type C and K with tx AG41 Type C and K no tx AG42 Code 16K disable AJ0 enable AJ1 Code 49 disable AM0 enab...

Страница 159: ...eeper Control For Radio Response normal BF0 only good decode BF1 only good reception BF2 off BF3 Single Store disable RO0 one attempt RO1 two attempts RO2 three attempts RO3 four attempts RO4 five att...

Страница 160: ...l 5 bars PQ OP 2 5 matrix 3 bars EAN 8 QR AB EAN 13 UPC A BC CD UPC E EAN 8 with 2 ADD ON DE JK EAN 8 with 5 ADD ON EAN 13 with 2 ADD ON KL LM EAN 13 with 5 ADD ON UPC A with 2 ADD ON MN FG UPC A with...

Страница 161: ...ABC CODABAR RS ST Code 128 EAN 128 TU kl Code 93 CIP 39 UV YZ CIP HR Code 32 ef XY ISBT 128 fg MSI Z Plessey Anker Plessey Standard op ab Delta IBM Telepen cd de Code 16K Code 11 pq bc Code 49 RSS Ex...

Страница 162: ...CODE IDENTIFIER TABLE tu RSS Limited RSS 14 Linear and Stacked vw uv...

Страница 163: ...0B 5 35 60 FF 0C 6 36 a 61 CR 0D 7 37 b 62 SO 0E 8 38 c 63 SI 0F 9 39 d 64 DLE 10 3A e 65 DC1 11 3B f 66 DC2 12 3C g 67 DC3 13 3D h 68 DC4 14 3E i 69 NAK 15 3F j 6A SYN 16 40 k 6B ETB 17 A 41 l 6C CA...

Страница 164: ...C HEX AND NUMERIC TABLE 01 0 12 23 1 2 34 45 3 4 56 67 5 6 78 89 7 8 9 AB 9 A BC CD B C DE EF D E FG F Backspace Cancels an incomplete configuration sequence...

Страница 165: ...25 Rugdetrekket 2 4600 K ge 135 70 Stockholm 3370 Vikersund Tel 45 70 222 555 Tel 46 8 742 20 55 Tel 47 32 78 12 11 Fax 45 70 222 666 Fax 46 8 742 21 56 Fax 45 70 222 666 www delfi com info delfi com...

Отзывы: