11
delfast.com
TROUBLE
SHOOTING
TROUBLE SHOOTING
Fault & Cause
Remedy
Charger gets hot, makes noise or starts to smoke.
CAUSE
•
The charger is damaged and should not be used.
•
Unplug the charger immediately and replace it with
a new charger
Tool will not cycle, the indicator LED is green and the fan runs
•
Fuel cell is empty
•
Spark wire is loose or dirty.
•
Replace with a new fuel cell.
•
Return to authorised service agent or manufacturer
for repairs.
Work contact element is not fully depressed and the tool
cannot be used.
•
The work contact element is bent or the track of the
safety mechanism is sticky, caused by dirt build up.
•
Clean the safety track.
•
If above does not work, return to authorised service
agent or manufacturer for repairs.
Tool operates normally, but no fastener is driven.
•
Wrong type of fasteners were used.
•
Fastener is jammed
•
The pusher did not engage
properly with the nail strip.
•
The cylinder needs cleaning.
•
Change to correct fastener specification.
•
Clear the jammed nail before use.
•
Adjust to full engagement.
•
Return to authorised service agent or manufacturer
for repairs.
Combustion chamber is not returning to start position.
•
The work contact element is bent or dirty.
•
Clean the safety track.
•
Check the work contact element and have it
repaired
or replaced by authorised service agent or
manufacturer.
Driver did not return to initial position, high misfire frequency.
•
Issue with fuel cell.
•
Tool is dirty.
•
The tool may be over heated.
•
Check and replace fuel cell.
•
Clean the tool with proper cleaning fluid.
•
Return to authorised service agent or manufacturer
for repairs.
Tool appears to be losing power.
•
Issue with fuel cell.
•
The tool may be over heated.
•
Check fuel cell.
•
Return to authorised service agent or manufacturer
for repairs.
For failures other than above situation, please stop using the tool and contact authorised service agent or manufacturer.
Содержание NAC-CN90
Страница 15: ...13 delfast com CORDLESS HOW TO...