Mounting:

Determine the optimum location for your pump.
1. The pump should be mounted in a dry place and away 

from any source of heat. If an enclosure is used, special 
instructions for cooling the motor may be necessary. Consult 
the Factory.

2. Do not subject the pump to extreme high or low (freezing) 

temperatures while in operation. (Operating ambient 
temperature range is 32° F to 115°F).

3. The pump may be mounted horizontally with the outlet port on 

the right when viewed from the pump end or with the pump 
above the mount, or vertically with the pump above or below 
the motor.

Plumbing:

1. Use suction hose on inlet of pump. We recommend use of 

flexible tubing with proper pressure rating.

2. Pump will prime only if all pressure is relieved from outlet port.
3. It is recommended that pure water be pumped or an in-line 

sediment filter (50 mesh) be installed at the inlet side to keep 
foreign debris out of the system. If a check valve is installed 
in the plumbing, it must have a cracking pressure of no more 
than 2 psi (0.14 bar).

4. Avoid any sharp bends which may crimp tubing and restrict 

flow. Use 90° elbow fittings if necessary.

5. The pump should always be mounted prior to any 

components which could introduce particles to the water; 
thus, preventing them from entering the pump chambers and 
possibly causing clogging.

Electrical:

1. The 7800 series pumps are designed for intermittent duty. 

Make sure that “OFF” periods are sufficient. Refer to Rapid 
ON/OFF Operation. Consult the factory for particular data and 
design criteria.

2. Be sure power supply used is adequate for the application.
3. Pump ratings are based off alternator charged battery which 

supplies 13.7 volts.

4. Each single drop in voltage is a reduction in motor speed thus 

reducing pump performance. 
(1 volt decrease = 200-300 loss in RPM)

5. Higher operating flow and pressure increases amp draw.

Installation and Operation 
Precautions:

1. The pump is equipped with a pressure sensing demand 

switch that controls the maximum operating pressure. 

2. In addition, never subject the pump to pressures above 125 

PSI (8.5 bars).

3. As long as there is inlet water pressure, the pump will not stop 

forward flow of water even if the motor is turned off. Be sure 
the system has positive means of shutting off water supply.

4. Do not operate pump in an explosive environment. Arcing 

from the motor brushes, switch or excessive heat from an 
improperly cycled motor may cause an explosion.

5. Do not locate the pump motor near low temperature plastics 

or combustible material. The surface temperature of the motor 
may exceed 250°F (120°C).

6. Do not pump gasoline or other flammable liquids. Pump head 

materials are designed for use with water only. Do not use 
with petroleum products.

7. Do not assume fluid compatibility. If the fluid is improperly 

matched to the pumps’ elastomers, a leak may occur.

8. To prevent electrical shock, disconnect power before initiating 

any work. In the case of pump failure, the motor housing and/
or pump fluid may carry high voltage to components normally 
considered safe. Therefore, always consider electrical shock 
hazard when working with and handling electrical equipment. 
If uncertain, consult an Electrician. Electrical wiring should only 
be done by a qualified electrician per local and state electrical 
codes.

Installation Recommendations

Installation and Operation

1. Turn off water supply.
2. Cut flexible tubing in sufficient length to avoid any stress on 

the tubing where it connects to the pump or the fitting on any 
accessory.

3. Insert tubing into pump ports. If fittings are John Guest type, 

be sure tubing is inserted past the resistance point until it 
bottoms out against the port stop. If compression fittings 
with threaded nuts are used, insert tubing until it bottoms out 
in the port and hand tighten the compression nut until the 
connection is tight. Then use a wrench to tighten the nut 1/2 
turn clockwise or follow the wrench tightening instructions 
provided by the fitting manufacturer.

4. The pump is now ready for operation. Turn on water supply to 

allow water to flow to the pump.

5. If the power source is a transformer, plug the appropriate 

supplied/approved transformer into the receptacle and 
connect the pump to the transformer. If the power source is 
not a transformer, connect the pump to the appropriate power 
source. Open the discharge or dispensing valve. Allow water 
to circulate, purging any entrapped air.

6. The pump will now start building pressure. Operating pressure 

will vary with flow rate, flow valve, feed-water pressure and line 
voltage. Check for fitting leaks.

7. If compression fittings with threaded nuts are used, observe 

any leaks after pump has run for approximately 15 minutes. 
Further tighten compression nuts approximately 1/8 to 1/4 
of a turn on all fittings in the system. Wait 15 minutes and 
repeat the leak check.  Note: Further adjustments should 
not be necessary although it may take several days of 
operation before all the air has been purged and the system is 
stabilized.

8. Adjusting the Pressure Switch. Should the pressure switch 

OFF setting vary with use and time to an unsuitable value, 
it may be adjusted for optimum performance. Turn the 
setscrew clockwise to increase the OFF pressure setting 
and counter clockwise to decrease. The screw should not 
be adjusted more than one half turn without consulting the 
Factory. Excessive adjustment of the pressure switch could 
cause low system pressure, rapid cycling ON/OFF operation, 
and reduced pump and motor life. Damage may occur. The 
Warranty does not cover improper adjustment of the pressure 
switch.

Servicing:

Every Year: Check system against operating standards.
Every 2-3 Years: We recommend replacing the diaphragm  
and checking against operating standards.

Troubleshooting Guide

Pump will not Start

 

Check: 
• 

Correct

 voltage (±10%) and electrical connections 

• 

Fuse

 or breaker  

• 

Pressure

 switch operation and correct voltage at switch 

 or motor for open or grounded circuit 

• 

Locked

 drive assembly

Pump will not Prime

 

(No discharge with motor running) 

Check: 
• 

Debris

 in strainer 

• 

Restriction

 (kinks) in inlet/outlet tubes 

• 

Debris

 or swelling in inlet/outlet valves

Pump will not Shut Off 

(Output line closed and no leaks) 

Check: 
• 

Air

 trapped in outlet line or pump head 

• 

Correct

 voltage to pump 

• 

Debris

 in pump inlet/outlet valves 

• 

Loose

 drive assembly or pump head screws 

• 

Pressure

 switch operations/adjustments

Leaks from Pump Head or Switch

 

Check: 
• 

Loose

 screws at switch or pump head 

• 

Switch

 diaphragm ruptured or pinched 

• 

Punctured

 diaphragm if 

 is present

Replacement Parts 

7801,7811,7802,7812,7822

1

 

Lower Housing

  ............................................................................................................................................ 

 

 

7801/7811 Demand or Bypass ....................................................................................... LHA-7801 

 

 

 

 

7802/7812 Demand or Bypass ....................................................................................... LHA-7802 

 

 

7822/7823 Demand or Bypass ....................................................................................... LHA-7822 

 

2

 

Valve Assembly 

 ........................................................................................................................................... 

 

 

7800 Series (all models) .................................................................................................. VHA-7800 

 

3

 

Upper Housing

  ............................................................................................................................................ 

 

 

7801/7802/7822 Series w/Pressure Switch ...............................................................UHA-7802-PS 

 

 

 

 

7801/7802/7822 w/Bypass ........................................................................................ UHA-7802-B 

 

 

7811/7812/7832 Series w/Pressure Switch ...............................................................UHA-7812-PS 

 

 

 

 

7811/7812/7832 Series w/Bypass .............................................................................. UHA-7812-B

4

 

Mounting Screws

 .......................................................................................................................................  

 

 

8-32 X 1” .......................................................................................................................... J78-051 

 

 

 

10-32 X 1 1/2“ .................................................................................................................. J78-050 

3

5

 

Complete Pump Head w/Threaded Ports

 .................................................................................................... 

 

 

7811 w/Pressure Switch ............................................................................................. PH-7811-PS 

 

 

 

 

7811 w/Bypass............................................................................................................. PH-7811-B 

 

 

7812 w/Pressure Switch ............................................................................................. PH-7812-PS 

 

 

 

 

7812 w/Bypass............................................................................................................. PH-7812-B 

 

 

 

 

 

 

 

 

 

 

 

 

Complete Pump Head w/Quick Attach Ports

 .............................................................................................. 

 

 

7801 w/Pressure Switch ............................................................................................. PH-7801-PS 

 

 

 

 

7801 w/Bypass............................................................................................................. PH-7801-B 

 

 

7802 w/Pressure Switch ............................................................................................. PH-7802-PS 

 

 

 

 

7802 w/Bypass............................................................................................................. PH-7802-B 

 

 

7822 w/Pressure Switch ............................................................................................. PH-7822-PS 

 

 

 

 

7822 w/Bypass............................................................................................................. PH-7822-B

6

 

12 VDC Motor

  ............................................................................................................................................. 

 

 

7800 Series w/Connector, No Switch,  ............................................................................. M12-78B 

 

 

7800 Series w/Switch and Connector ............................................................................... M12-78C

7

 

Pressure Switch

  .......................................................................................................................................... 

 

               7800 Series (all models) .................................................................................................7800-PSW

 

Item  Description 

Part Number 

Qty

PowerFLO

 7800 Series

PowerFLO

 7800 Series

PowerFLO

 7800 Series

Toll  Free:  1-866-DELAVAN  (335-2826)  •  Toll  Free  Fax:  1-888-726-5906  •  delavanagpumps.com

Toll  Free:  1-866-DELAVAN  (335-2826)  •  Toll  Free  Fax:  1-888-726-5906  •  delavanagpumps.com

Отзывы: