After Sales Care and Technical Support:
For the UK market only: Tel.
01491 821 821 -
email:
The installation guide is available on: www.delabie.co.uk
For all other markets: Tel.
+33 (0)3 22 60 22 74 -
email:
The installation guide is available on: www.delabie.com
MAXIMUM TEMPERATURE LIMITER (FIG. D and G)
The mixer is delivered with the temperature limiter engaged. To override it:
• Remove the push-button control
j
(
Fig. D
) by unscrewing the grub screw
k
(without fully removing it)
using a 2.5mm Allen key.
• Remove the index ring
o
(
Fig. G
) and turn it anti-clockwise to increase the temperature.
• Replace the index ring
o
(
Fig. G
) and the push-button control
j
(
Fig. D
).
BEWARE:
Do not remove the index ring
o
(
Fig. G
).
REMEMBER
•
Our mixers must be installed by professional installers
in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
•
Sizing the pipes correctly
will avoid problems of flow rate, pressure loss and water hammer
(see calculation table in our brochure and online at www.delabie.com).
•
Protect the installation
with filters, water hammer absorbers and pressure reducers to reduce
the frequency of maintenance (recommended pressure from 1 to 5 bar maximum).
•
Install stopcocks
close to the mixer to facilitate maintenance.
• The pipe work, stopcocks, bib taps and all sanitary fittings should be checked at least once a year,
and more frequently if necessary.
MAINTENANCE & CLEANING
•
Cleaning chrome:
do not use abrasive, chlorine or any other acid-based cleaning products.
Clean with mild soapy water using a cloth or a sponge.
•
Frost protection:
drain the pipes and operate the mixer several times to drain any remaining water.
MAINTENANCE
Removing the mechanism (Fig. D):
• Unscrew the grub screw
k
(without fully removing it) using a 2.5mm Allen key.
• Unscrew the cartridge
l
two full turns then shut off the Hot and Cold water supply and continue
to unscrew the cartridge
l
(
Fig. D
), to remove the mechanism.
Foreign bodies in the pipe work may cause the mechanism to malfunction:
- Automatic shut-off takes too long or there is continuous flow (Fig. H):
• Clean the inside of the delay case
p
using a clean, dry cloth and clean the calibrated groove
q
with
a non-metallic, sharp point.
• Check that the lip seal
r
and the seats
s
are in good condition.
• Don’t forget to replace the spring
t
.
- Dripping or a constant trickle (Fig. H):
• Clean the seats
s
or replace if damaged.
• Don’t forget to replace the spring
t
.
BEWARE:
do not grease the inside of the mechanism.
- Problems with achieving the correct temperature (Fig. A):
• Ensure that the hot and cold water pressures are balanced (ΔP < 1 bar)
• Check that there are no foreign bodies in the non-return valves
.
• Check the non-return valves at least once a year.