CHANGING THE PUMP FILTER
The ZO–200 Pump filter may require cleaning or replacing up to every
six months depending on the purifier’s exposure.
Disconnect Power
before servicing the unit.
The filter can be removed and replaced by
accessing it through the hole in the back of the purifier with a pair of
tweezers or pliers. If there is no filter access hole on the back of your
purifier, remove the pump by removing the two mounting screws on
the back of the unit. Be careful not to over-tighten the screws when
re-mounting the pump.
UNIT SPECIFICATIONS
Electrical Specs:
120 vac, .1 amps, 12 watts
Cabinet:
Aluminum, powder coated finish
Unit Dimensions:
9H X 12.3W X 3.9D
Unit Weight:
4 lbs
Shipping Weight:
5 lbs
Operating Temperature:
35
0
F to 100
0
F
Compressor Provides:
5 scfh @ 2 psi
PARTS LIST
Ozone Cell & P.S.
9-1056-01
Ozone Supply Tubing
7-0723
Dispersion Stone
7-0785
Suction Cup
7-0839
Pump 5-0782
Pump Filter
7-0877
Ball Chain
8-0304
Ozone Supply Check Valve
7-1140-01
Thru-Wall Disperser Assembly
9-0152
Thru-Wall Disperser Element
7-0422