background image

Table of Contents

DELZONE

®

 Eclipse 1, 2, & 4 Corona Discharge Ozone Generators

SECTION 1

General Information

1A  Description ......................................................................... 1
1B  Specifications .................................................................... 1
1C  Warranty Summary .......................................................... 1

SECTION 2

Installation

2A  Location .............................................................................. 1
2B  Mounting ............................................................................ 1
2C  Electrical ............................................................................. 1
2D  Plumbing ............................................................................ 2

SECTION 3

Operation

3A  General ............................................................................... 2
3B  Initial System Start-Up ..................................................... 2
3C  Normal Operation ............................................................. 2
3D  System Shut-Down ............................................................ 3
3E  Water Chemistry ............................................................... 3

SECTION 4

Maintenance & Service

4A  System Electro-Mechanical Overview ............................ 3
4B  System Maintenance ........................................................ 3
4C  Generator Servicing .......................................................... 3
4D  Trouble Shooting ............................................................... 4

SECTION 5

Replacement Parts and Ordering 

Information

5A  Ordering Information ........................................................ 5
5B  Standard Replacement Parts List .................................. 5

Warranty

 .....................................................................

5

IMPORTANT SAFETY INSTRUCTIONS

Read and Follow All Instructions

• Read this manual completely before attempting installation.

 All permanent electrical connections should be made by a qualified electrician.

• For cord and plug-connected units, connect to a grounded, grounding type receptacle only. If the DELZONE

®

 Eclipse electrical connection is to 

be attached to the pool controls, be sure the pool controls are protected by a Ground Fault Circuit Interrupter (G.F.C.I.). If the DELZONE

® 

Eclipse 

is connected to an independent electrical supply, then a G.F.C.I. must be installed between the DELZONE

®

 Eclipse and the electrical supply.

• Do not bury cord.

• Warning - To reduce the risk of electrical shock, replace damaged cord immediately.

• A pressure wire connector is provided on the outside of the unit to permit connection to a minimum No. 8 AWG (8.4 mm

2

) solid bond-

ing conductor between this point and any metal equipment, metal enclosures of electrical equipment, metal water pipes, or conduit 

within five (5) feet (1.5m) of the unit as needed to comply with local requirements.

• Install at least 5 feet (1.5 meters) from wall of pool water using nonmetallic tubing. Install ozone generator no less than one (1) foot 

above maximum water level to prevent water from contacting electrical equipment. Install in accordance with the installation instruc-

tions.

• Follow all applicable electrical codes.

• Electric shock hazard. Be sure to turn power OFF and disconnect from power source before any service work is performed. Failure to 

do so could result in serious injury or death.

• The DELZONE

® 

Eclipse must be installed in an outdoor location, or indoors in a forced air ventilated room, and installed so that the 

orientation is exactly as shown in Figure 1. Install to provide water drainage of generator to protect electrical components.

• Mount the DELZONE

® 

Eclipse so that it is inaccessible to anyone in the pool. Never attempt any servicing while unit is wet.

• Plastic ozone supply tubing is supplied with the Eclipse. Never replace this tubing with metal tubing.

• Warning - Short-term inhalation of high concentrations of ozone and long term inhalation of low concentrations of ozone can cause 

serious harmful physiological effects. DO NOT inhale ozone gas produced by this device.

 For your safety, do not store or use gasoline, chemicals or other flammable liquids or vapors near this or any other appliance.

SAVE THESE INSTRUCTIONS!

C

Содержание Eclipse-1

Страница 1: ...DEL Ozone SAN LUIS OBISPO CA 93401 USA 800 676 1335 Fax 805 541 8459 111904 4 0308 Rev F Corona Discharge Ozone Generators 1 2 4 INSTALLATION OPERATION MANUAL...

Страница 2: ...of the unit to permit connection to a minimum No 8 AWG 8 4 mm2 solid bond ing conductor between this point and any metal equipment metal enclosures of electrical equipment metal water pipes or conduit...

Страница 3: ...of direct Sunlight Locate generator out of reach of sprinklers or drainage spouts Allow sufficient access for maintenance and all tubing and electrical wires Ozone generator should be installed at lea...

Страница 4: ...the ozone supply tubing to the port marked OZONE OUT see Bottom View Figure 4 NOTE Plumbing the Ozone Line to the incorrect port will cause damage to the ozone generator 2D 4 Flowmeter Connect the flo...

Страница 5: ...ely2years if the pool system operates 24 hours day 365 days of the year 4B 3 Regularly check the flowmeter for proper flow and inspect ozone supply tubing for cracks or wear Replace ozone supply tubin...

Страница 6: ...valve replace the check valve with a new one Symptom LED Indicator has turned red a This means that the power supply of that specific ozone module is no longer drawing power and needs to be replaced...

Страница 7: ...ssitated by faulty installation improper maintenance improper operation misuse abuse negligence accident fire repair materials and or unauthorized accessories c any such products installed without reg...

Страница 8: ......

Отзывы: