8. Change the mode settings of the controller manually
The controller is delivered pre-programmed in 230V dimmer mode. Depending on which type of light or operating
device you want to connect, you have to set the required mode (230V switching, 230V dimming, dimming with
0-10V / 1-10V or sensor mode) accordingly. You can do this via the APP (see . Page 19) or manually as listed
below.
The desired mode can be changed by holding down a possibly already connected button as shown in the drawing.
Alternatively, you also have the option of using a wire bridge between the respective connection terminals to set
the desired mode.
Change mode setting manually:
The modes are activated by pressing the
button or by creating a cable bridge of
min. 60 seconds set.
Mode selection:
Hold down button 1 or jumper (C + 1) for 60 seconds = Mode „SWITCH 230V“ (see page 6)
Hold down button 2 or jumper (C + 2) for 60 seconds = Mode „230 DIM“ (see page 7) (delivery condition)
Hold down button 3 or jumper (C + 3) for 60 seconds = Mode „DIM 0-10V/1-10V (see page 8)