background image

Section II - Installation 

GENERAL INFORMATION 

Scope 

This section provides detailed installation and interconnection instructions for the DT100 Analog 
Telephone Handset. Please read this manual carefully before beginning any installation to prevent damage 
and post installation problems. Installation of this equipment requires special knowledge and tools. 

 

Installation Requirements 

The DT100 requires specialized knowledge and tools for an effective installation. An appropriately rated 
Certified Repair Station must install this equipment in accordance with applicable regulations. Deklin 
Technologies, Inc warranty is not valid unless installed by an authorized FAA approved repair station. 
Failure to follow any of the installation instructions, or installation by a non-certified individual or 
agency, will void the warranty and may result in a non-airworthy installation. 

 

Unpacking and Inspection 

Use care when unpacking the equipment. Inspect the unit and all the parts supplied for visible signs of 
shipping damage. Examine the unit for loose or broken pieces. Verify the correct quantity of components 
supplied with the list in Section I. If any claim is to be made, save the shipping material and contact the 
freight carrier. DO NOT return any items damaged in shipping to Deklin Technologies, Inc. If any items 
show signs of external shipping damage, contact Deklin Technologies, Inc for a replacement. Do not 
attempt to install a damaged unit. Equipment returned to Deklin Technologies, Inc for any other reason 
should be shipped in the original packaging, or other UPS approved packaging. 

 

INSTALLATION PROCEDURES 

Cooling Requirements 

Forced air-cooling is not required for the DT100. However, the equipment should be kept away from heat 
sources without adequate cooling provided. (i.e. defrost or heating ducts, dropping resisters, heat 
producing avionics.) 

 

Mounting Requirements 

The DT100 must be mounted inside the pressure vessel in a temperature controlled environment unless 
the aircraft’s service ceiling is less than 25,000 feet. 
 
The DT100 must be rigidly mounted to a secure structure in accordance with FAA Advisory Circular AC 
43.13-2A. The unit should be mounted in an area with adequate clearance for the unit and associated 
wiring. 
 
The locking base must be firmly mounted using two 6/32 screws from behind the mounting surface into 
the pem-nuts of the base. The drop-in cradle is mounted using two 8/32 screws through the base and 
mounting surface into locking 8/32 nuts or fasteners. 
 

Connector Assemblies 

The curly cord assembly comes complete with 2 each RJ11/6 plugs on either end, or, an RJ11/6 on one 
end and a 9-pin D-Sub connector on the other. It does not require additional assembly.  

 

When using the locking base, the mating RJ11/6 jack or 9-pin D-Sub connector should be mounted in 
close proximity to the base assembly so as not to cause any tension to the curly cord when the handset is 
locked into the base assembly.  

 

Deklin Technologies, Inc. 

2008 

Содержание DT100

Страница 1: ...100 ANALOG TELEPHONE HANDSET Installation and Operations Manual Rev 1 4 Dec 31 2008 Deklin Technologies Inc 413 Chesterfield Lane North Aurora IL 60542 Tel 630 844 1760 Fax 630 844 1795 www deklintech com ...

Страница 2: ...RIPTION DATE APPROVAL 1 0 Initial Release Oct 2005 JAD 1 1 Increased Warranty 1 5 2007 TJD 1 2 Powering Up Unit 5 31 2007 TJD 1 3 Software Update v1 31 New Cradle 5 9 2008 TJD 1 4 Operational Changes v1 35 12 31 2008 TJD ...

Страница 3: ..._______________________________________________________ 4 Post Installation Check_____________________________________________ 4 Operational Checkout _____________________________________________ 4 Section III Operation _______________________________________ 5 OPERATION __________________________________________________________ 5 Handset Volume__________________________________________________ 5 ...

Страница 4: ...________________ 10 RJ11 6 Mating Connector ARJ11 View from front ______________________ 10 DT100 2XX w RJ11 to DB9 ______________________________________ 11 DT100 3XX w RJ11 to DB9 ______________________________________ 11 Appendix B_______________________________________________ 12 MECHANICAL DRAWINGS______________________________________________ 12 Handset ______________________________________...

Страница 5: ...QUIPMENT DESCRIPTION The Deklin Technologies Inc DT100 is an analog telephone handset for 1 line using a standard Tip Ring interface also referred to as POTS Plain Old Telephone Set The DT100 Analog Telephone Handset can be used with any telephone system that provides a standard Tip Ring analog interface The DT100 standard functions 2 wire analog POTS interface 21 33 VDC input 27 5 Nominal Lighted...

Страница 6: ...val Temperature 40F to 158F 40C to 70C Humidity 95 Altitude 35 000ft Max Weight 0 8 Lbs 0 36 kg w Base Cord Connectors RJ11 6 Jack OR 9 Pin D Sub Connector Input Specifications Input Voltage 22 33VDC 27VDC Nominal Current 0 5A Nominal Fuse Rating 1A Interface Specifications Telephone Line Inputs 1 Telephone I F 2 Wire Analog POTS Distortion 5 Ringing Voltage 90VAC 15V no load On Hook Voltage 48VDC...

Страница 7: ...with RJ11 6 one end D Sub 9 Male one end 1 each IK200 Install Kit D Sub 9 Female w Locking Hardware OR DT100 3XX 1 each DT100 Handset with Locking Base 1 each 6 Coil Cord with RJ11 6 one end D Sub 9 Male one end 16 pigtail 1 each IK200 Install Kit D Sub 9 Female w Locking Hardware EQUIPMENT REQUIRED BUT NOT SUPPLIED 1 each 1 amp circuit breaker Fuse 1 each Airborne Telephone System with 2 wire Tip...

Страница 8: ... Inc for a replacement Do not attempt to install a damaged unit Equipment returned to Deklin Technologies Inc for any other reason should be shipped in the original packaging or other UPS approved packaging INSTALLATION PROCEDURES Cooling Requirements Forced air cooling is not required for the DT100 However the equipment should be kept away from heat sources without adequate cooling provided i e d...

Страница 9: ...th transmitter coax lines Do not bundle any lines from this unit with any other audio or high voltage power lines Do not bundle any lines from this unit with 400 Hz synchro wiring or AC power lines such as strobes or inverters Do not position this unit or route wiring from this unit next to any device with a strong alternating magnetic field such as an inverter Use shielded wire where shown and gr...

Страница 10: ...required Use the buttons to select the Ringer Volume level Ringer Tone To select a Ringer Tone press the MENU button until Ringer Tone appears on the screen Several presses may be required Use the buttons to select the Ringer Tone Flash The FLASH button provides a 600ms break during an On Hook condition Refer to the Operations Instructions of your telephone system or Network Provider for informati...

Страница 11: ...e but is not currently connected to an outside call then press the HOOK button and listen for a dial tone Dial telephone number Refer to the Operations Instructions of your telephone system or Network Provider for information on phone number format Answering Incoming Call Lift handset The handset should come Off Hook Start conversation If the handset is already removed from the locking base but is...

Страница 12: ...he handset is already removed from the cradle but is not currently connected to an outside call then press the HOOK button and listen for a dial tone Dial telephone number Refer to the Operations Instructions of your telephone system or Network Provider for information on phone number formats Answering Incoming Call Lift handset The handset should come Off Hook Start conversation If the handset is...

Страница 13: ... user may cancel and revert back to the Logo screen by pressing MENU 1 Press MENU to enter Phone Book Entry Mode 2 Follow instructions on screen In this case press the 1 key for Edit 3 Use arrows to select the entry you wish to modify and press the STORE button when done 4 The handset will then display the name field for modification Alter name using keypad The arrow is backspace if you make a mis...

Страница 14: ...ling insurance brokerage fees duties and taxes for shipments outside the continental United States is the responsibility of the customer Deklin Technologies Inc shall not be liable for incidental or consequential damages This warranty does not cover a defect that has resulted from improper handling storage or preservation unreasonable use or maintenance This warranty is void if there is any attemp...

Страница 15: ...Appendix A CABLE ASSEMBLIES DT100 1XX w RJ11 to RJ11 RJ11 6 Mating Connector ARJ11 View from front Deklin Technologies Inc 2008 10 ...

Страница 16: ...DT100 2XX w RJ11 to DB9 DT100 3XX w RJ11 to DB9 Deklin Technologies Inc 2008 11 ...

Страница 17: ...Appendix B MECHANICAL DRAWINGS Handset Locking Base Deklin Technologies Inc 2008 12 ...

Страница 18: ...Cradle Deklin Technologies Inc 2008 13 ...