Deif TDU 107 Скачать руководство пользователя страница 33

4.11.1 More settings

Views or configures the additional settings for the display.

09/05/2019 - 12:46:16

DEIF

24 %

96 %

255 h

Screensaver

Start / stop buttons on home
screen

AOP page shortcut on home
screen

USA Tier4 compliance

Clock master

Breaker buttons on home

Parameter page shortcut on

Auto jump to sync scope

home screen

screen

Master / slave controller
manual switch

TDU 107

1

11

10

9

3

4

5

2

7

8

6

No.

Item

Use

Notes

Return 

 Returns to previous display.

Settings 

Toggles on or off additional settings. 

 or 

 Setting enabled.

 or 

 Setting disabled.

Screensaver 

 or 

Enables or disables the screensaver. 

Start / Stop buttons 

 or 

Shows or hides the start / stop buttons on the home page. 

AOP shortcut 

 or 

Shows or hides the AOP button on the home page. 

Tier 4 compliance 

 or 

Enables or disables the Tier 4 compliance.
Enable this to automatically display the Exhaust After-treatment Dashboard if an
alarm becomes active.

Master/slave
controller manual
switch 

 or 

Enable

: There is a redundant AGC.

Buttons on the 

Home

 page show whether the master or slave AGC is the active

controller.

You can select the master and slave AGC IP addresses on the 

Setup > Connect

to Controller > Communication settings

 page.

Disable

: There is no redundant AGC.

Auto jump to sync
scope 

 or 

Enables an automatic jump to the synchronisation scope when a breaker is
synchronising.
After synchronisation the page automatically returns to the control panel.

Parameter shortcut 

 or 

Shows or hides the Parameter button on the home page. 

10 

Breaker buttons 

 or 

Shows or hides the breaker buttons on the home page. 

11 

TDU 107 clock
master

Select the master clock for the system. 

OPERATORS MANUAL 4189341218F EN 

Page 33 of 40

Содержание TDU 107

Страница 1: ...OPERATOR S MANUAL TDU 107 Touch Display Unit 4189341218F...

Страница 2: ...9 2 2 2 Status bar 10 2 2 3 Core connections 11 2 2 4 Extended connections 11 3 Operating the system 3 1 Menus 13 3 1 1 Return back navigation 13 3 2 Keyboards 14 3 2 1 Text keyboard 14 3 2 2 Value ke...

Страница 3: ...4 4 13 Language translations 35 4 13 1 Introduction 35 4 13 2 Before you begin 35 4 13 3 Create or edit language translation 36 4 14 Export or import settings 37 4 14 1 Introduction 37 4 14 2 Before y...

Страница 4: ...cation 6 00 x or later AGC 4 Controller application 4 76 x or later TDU 107 Core TDU 107 Extended Display unit application 1 3 7 x or later 1 1 3 List of technical documentation Document Contents Data...

Страница 5: ...risk situation If the guidelines are not followed these situations could result in minor or moderate injury NOTICE This highlights an important notice Make sure to read this information 1 1 6 Symbols...

Страница 6: ...rriding alarm actions Risk of damage to genset or equipment Manually overriding alarm actions could cause damage to the genset or equipment Do not use manual control to override the alarm action of an...

Страница 7: ...s the most recent and up to date information about the product DEIF does not take responsibility for the accuracy of translations and translations might not be updated at the same time as the English...

Страница 8: ...4 82 81 80 79 72 71 69 70 68 67 65 66 62 63 59 60 61 58 56 57 55 53 54 64 52 51 50 49 47 46 44 43 45 48 41 40 38 37 39 42 Service port Display Ethernet PMS CAN Engine CAN Power Self check ok Alarm inh...

Страница 9: ...2 2 Layout 2 2 1 Unit Figure 2 2 TDU 107 layout No Item Notes 1 Touch screen area Operate the controller by touching the screen 2 Frame OPERATORS MANUAL 4189341218F EN Page 9 of 40...

Страница 10: ...tment Dashboard Opens Exhaust After Treatment Dashboard Shortcut 7 Alarm s Opens Alarms Shortcut 8 Language Opens Language Shortcut 9 Date and Time Shows the controller Date and Time NOTE Only shown i...

Страница 11: ...86 83 84 82 81 80 79 72 71 69 70 68 67 65 66 62 63 59 60 61 58 56 57 55 53 54 64 52 51 50 49 47 46 44 43 45 48 41 40 38 37 39 42 Service port Display Ethernet PMS CAN Engine CAN Power Self check ok Al...

Страница 12: ...high data transfer connection it is possible to connect the TDU 107 Extended version directly to the controller and connect a service PC to the TDU 107 AGC 4 example wiring for a system configuration...

Страница 13: ...menus No Item Use Notes 1 Features Shows available features or other menus Selects feature or menu 3 1 1 Return back navigation Some displays allow you to go back to the previous feature or menu Use...

Страница 14: ...tem Use Notes 1 Text Shows the text you are entering 2 Keyboard Selects letters numbers or symbols 3 Cursor Moves the cursor to the left Moves the cursor to the right 4 Enter Confirms the text entered...

Страница 15: ...n enter 4 Maximum value Shows the maximum value you can enter 5 Increase Decrease Allows you to increase or decrease the value Increase value Decrease value 6 Cursor Moves the cursor to the left Moves...

Страница 16: ...the DEIF email to complete the software download 3 The software package is provided as a zipped archive zip file Do not unzip this file 4 If the old software in the TDU has a version number lower than...

Страница 17: ...generator 4 Breaker control Closes breaker Opens breaker 5 CAN ID Priority Shows the CAN ID and the priority number in power management applications Only shown in power management applications and no...

Страница 18: ...s 1 Instrument value to change Selects instrument to change 2 Refresh Refreshes the list of values 3 Scroll and search Scrolls page left Scrolls page right Searches for values 4 Save Saves the change...

Страница 19: ...Use Notes 1 Instrument value to change Selects instrument to change 2 Factory setting Returns the properties back to the factory default values 3 Save Saves the change 4 Instrument properties Configu...

Страница 20: ...te of the system in real time No Item Use Notes 1 Live system overview Shows the system state 2 Menu Opens the menu page NOTE Actual system shown depends upon your plant configuration OPERATORS MANUAL...

Страница 21: ...isplay 2 Search Opens search keyboard 3 Filter groups Opens groups of parameters 4 Refresh Reloads the list 5 Controller Settings List Scrolls settings up or down on this page 6 Clear filter group Cle...

Страница 22: ...right to increase or decrease the value 4 Settings Toggles on or off additional settings or Setting enabled or Setting disabled Cannot be changed 5 Write Writes the settings to the controller 6 Output...

Страница 23: ...filter groups you can use to filter the controller settings page No Item Use Notes 1 Filter groups Shows the list of filter groups Selects a filter group Returns to previous display OPERATORS MANUAL...

Страница 24: ...Acknowledge all alarms Acknowledges all unacknowledged alarms 3 Alarms list Scrolls the alarm list up or down 4 Alarm state Shows the state of the alarm Acknowledged alarm Unacknowledged alarm 5 Ackn...

Страница 25: ...p of the display No Item Use Notes 1 Alarm Shows the activated alarm 2 Alarms list Opens the Alarms list shortcut 3 Alarm settings Opens the Alarm settings shortcut 4 Acknowledge Acknowledges the alar...

Страница 26: ...36 48 1 2 3 4 5 7 8 9 10 6 No Item Use Notes 1 Return Returns to previous display 2 Filter Filters the list by either Alarms or Events only Shows only Alarms Shows only Events 3 DM1 EIC alarm list DM...

Страница 27: ...F Shows that a regeneration is needed 7 Diesel Particle Filter DPF Inhibit Shows that regeneration is inhibited 8 LIM LIMIT lamp 9 Diesel Exhaust Fluid DEF level Shows the level of the Diesel Exhaust...

Страница 28: ...safe operation limits for the alternator 3 Import Leading Opens the capacitive Q configuration 4 Export Lagging Opens the inductive Q configuration 5 Setting point Shows the numbered setting points 6...

Страница 29: ...status from the M Logic project condition s Green Green blink Yellow Yellow blink Red Red blink 3 LED name Edits the LED name 4 Button Operates the button if configured 5 Button name Edits the button...

Страница 30: ...previous display 2 Languages Shows the available active languages Selects the language for the display NOTE The actual languages shown must be both installed and active to be listed for selection Mor...

Страница 31: ...ssions Features of the display can be restricted to the AGC password levels No Item Use Notes 1 Return Returns to previous display 2 Scroll page Scrolls page up Scrolls page down 3 Feature permissions...

Страница 32: ...Use Notes 1 Return Returns to previous display 2 Display settings Edits the display settings Data and time format Number format Default Home page Theme code name Edits the date and time format for th...

Страница 33: ...ge 6 Tier 4 compliance or Enables or disables the Tier 4 compliance Enable this to automatically display the Exhaust After treatment Dashboard if an alarm becomes active 7 Master slave controller manu...

Страница 34: ...re hidden from use Selects a language 6 Hidden language s scroll page Scrolls page up Scrolls page down 7 Active language s list Shows languages that are active for use Selects a language 8 Active lan...

Страница 35: ...keep the delimiter It is important that the format and structure of the file entries remain the same TDU 107 specific entries that is to say for the display screen all start with a hash The first set...

Страница 36: ...wish to create 11 Open the file for editing with Notepad 12 Edit the texts that you wish to change 13 Save the updated translation file to your USB memory device 14 Safely remove your USB drive from y...

Страница 37: ...e into the USB port It takes a few moments to recognise the USB drive When recognised the USB icon is displayed on the status bar 4 Wait for the USB icon to be displayed on the status bar 5 Select con...

Страница 38: ...The TDU 107 must be restarted for the new configuration to be applied 7 Select Confirm to restart OPERATORS MANUAL 4189341218F EN Page 38 of 40...

Страница 39: ...o operate the TDU 107 displays the Access lock message in the status bar Configuration and operation can no longer be saved or changed Example page with Access lock shown AGC Access lock Access lock i...

Страница 40: ...therefore be disposed of properly In Europe the disposal of WEEE is governed by the WEEE directive issued by the European Parliament DEIF complies with this directive You must not dispose of WEEE as...